Research Article

Fault Diagnosis of Variable Load Bearing Based on Quantum Chaotic Fruit Fly VMD and Variational RVM

Table 3

Experimental data under different fault degrees.

Damage degreeMinorModerateSevere

Fault frequency calculated value (Hz)116.61116.61116.61
Measured value (Hz)116.5116.5116.5
[α, K][1800, 6][1600, 6][1400, 8]
Optimal IMFIMF4IMF4IMF6
Normalization center frequency0.45860.46240.4667
LMMSE0.48750.39940.3211