Research Article
Influence of Hydraulic Domain on Vibration Control and Overload Prediction of High-Speed Punching Press: Multidomain Modelling and Experiment
Table 2
Comparison of vibration quantity of punch press before and after installation of hydraulic system.
| Installation of hydraulic system | Vibration amplitude/equilibrium position of frame (mm) | Vibration amplitude/equilibrium position of slider (mm) | Difference between amplitudes of frame and slider (mm) | Relative distance between equilibrium positions of frame and slider (mm) | Relative vibration quantity (mm) |
| Before | 0.446/(−2.664) | 0.444/(−22.637) | 0.002 | 0.027 | 0.029 | After | 0.052/(−3.178) | 0.040/(−23.186) | 0.012 | −0.008 | 0.020 |
|
|