Research Article

Influence of Hydraulic Domain on Vibration Control and Overload Prediction of High-Speed Punching Press: Multidomain Modelling and Experiment

Table 2

Comparison of vibration quantity of punch press before and after installation of hydraulic system.

Installation of hydraulic systemVibration amplitude/equilibrium position of frame (mm)Vibration amplitude/equilibrium position of slider (mm)Difference between amplitudes of frame and slider (mm)Relative distance between equilibrium positions of frame and slider (mm)Relative vibration quantity (mm)

Before0.446/(−2.664)0.444/(−22.637)0.0020.0270.029
After0.052/(−3.178)0.040/(−23.186)0.012−0.0080.020