Research Article

Robust Optimum Design of Multiple Tuned Mass Dampers for Vibration Control in Buildings Subjected to Seismic Excitation

Table 5

Comparison between maximum interstory drift.

StoryUncontrolled structure (m)With control (m)Reduction (%)

10.03830.014861.35
20.03810.014761.39
30.03740.014162.30
40.03570.013263.05
50.03300.012063.50
60.02940.011560.80
70.02480.010756.74
80.01940.009153.29
90.01330.006849.32
100.00680.003745.65