Storeys where the five dampers fail under ANEs with different pulse periods.

DampersTp/T
0.30.50.81.01.21.52

BRBStorey 5, 6Storey 6Storey 5Storey 4, 3, 5, 2Storey 4, 3
VEDStorey 6Storey 4Storey 3, 4Storey 5, 4, 3
FDStorey 5
VDStorey 4
SCDStorey 5, 6Storey 5Storey 5, 4Storey 3, 4, 2, 5Storey 3, 2, 4Storey 3, 4, 2