Research Article

Comparison of Methodologies for the Detection of Multiple Failures Using Acoustic Images in Fan Matrices

Table 3

SVM accuracy rates of the individual faulty fan detection methodology with two faulty fans working situation of the matrix.

Individual faulty fan detection methodology: two faulty fans testsAccuracy rate (%)

Global87.9
Two faulty fans separation
 Case A: horizontal/vertical step distance (no central fan)89.5
 Case B: horizontal/vertical step distance (with central fan)89.3
 Case C: diagonal step distance84.3
 Case D: knight movement distance89.6
 Case E: row/column distance84.7
 Case F: diagonal distance92.5