Shock and Vibration / 2020 / Article / Tab 8 / Research Article
Effectiveness of Friction Dampers in Seismic and Wind Response Control of Connected Adjacent Steel Buildings Table 8 Peak top floor displacement and acceleration responses of dissimilar connected buildings for equal storey height under historical earthquake ground motions.
Frame Earthquake Peak top floor displacement, x n (cm) Peak top floor acceleration, ẍ n ( ) U A B C U A B C 5-5 MRF-BF Imperial Valley, 1940 11.49 2.37 3.88 3.17 1.51 0.83 0.88 0.99 Loma Prieta, 1989 26.67 9.78 14.37 14.02 3.70 1.42 1.91 2.10 Northridge, 1994 16.96 13.77 14.22 14.58 2.68 2.61 2.59 2.62 Kobe, 1995 12.10 7.60 8.89 8.74 1.72 1.53 1.51 1.55 20-20 MRF-BF Imperial Valley, 1940 22.18 9.19 11.17 11.93 0.79 0.79 0.76 0.79 Loma Prieta, 1989 81.23 52.99 56.80 65.99 2.10 1.71 1.63 2.09 Northridge, 1994 81.67 57.46 65.42 60.99 1.63 1.53 1.57 1.54 Kobe, 1995 37.41 23.67 24.76 24.21 1.31 1.12 1.29 1.30 5-5 BF-MRF Imperial Valley, 1940 3.36 2.13 2.33 2.27 1.44 1.13 1.06 1.16 Loma Prieta, 1989 7.15 4.28 5.19 4.90 2.65 1.56 2.00 1.91 Northridge, 1994 10.61 9.81 9.92 9.91 4.00 3.21 3.32 3.33 Kobe, 1995 8.97 6.17 5.89 5.97 2.94 2.01 1.86 1.87 20-20 BF-MRF Imperial Valley, 1940 15.72 9.36 11.79 11.84 0.77 0.66 0.73 0.69 Loma Prieta, 1989 46.08 43.59 41.61 48.97 1.86 1.69 1.78 1.74 Northridge, 1994 40.27 37.22 36.84 37.18 2.25 1.85 2.18 2.17 Kobe, 1995 33.50 24.01 25.00 24.72 2.08 1.33 1.65 1.51