Shock and Vibration / 2020 / Article / Tab 3 / Research Article
Experimental and Numerical Investigation of Flow Measurement Mechanism and Hydraulic Performance of Portable Pillar-Shaped Flumes in Rectangular Channels Table 3 Comparison of the measured and calculated flow rates at different contraction ratios.
ε H (cm)Q 1 (L/s)Q 2 (L/s) (%)0.4 8.18 5.04 5.20 3.32 10.18 7.03 7.31 4.07 12.03 9.06 9.48 4.74 13.60 11.14 11.48 3.06 15.08 12.94 13.48 4.16 16.46 15.17 15.45 1.88 17.71 17.08 17.32 1.36 18.92 18.97 19.19 1.16 20.01 21.01 20.94 0.35 21.31 23.06 23.10 0.18 22.18 25.14 24.58 2.22 23.20 27.03 26.36 2.46 0.5 6.91 5.03 4.94 1.82 8.65 7.04 7.01 0.55 10.18 9.07 9.03 0.44 11.53 11.12 10.96 1.43 12.75 12.94 12.82 1.00 13.98 15.15 14.79 2.37 15.19 17.05 16.83 1.27 16.25 18.97 18.69 1.45 17.18 21.05 20.39 3.16 18.41 23.08 22.70 1.64 19.31 25.06 24.45 2.40 20.18 27.08 26.19 3.30 0.6 6.22 5.02 4.98 0.85 7.71 7.03 6.96 0.98 9.10 9.07 9.00 0.75 10.32 11.15 10.95 1.75 11.52 13.00 13.00 0.02 12.48 15.14 14.72 2.79 13.61 17.05 16.85 1.20 14.71 19.01 19.02 0.04 15.57 21.02 20.77 1.18 16.56 23.03 22.87 0.70 17.44 25.08 24.78 1.19 18.37 27.04 26.87 0.62