Research Article

Effect of Blade Outlet Angle on Radial Force of Marine Magnetic Drive Pump

Table 3

RMS of radial resultant forces on the impeller and the blades.

FlowModelFi (N)Fb (N)Fb/Fi × 100

0.8Q25309.184.527.3
30321.986.927.0
35349.1108.531.1
40356.6110.631.0
ΔF47.526.1
1.0Q25261.479.030.2
30274.384.830.9
35295.293.531.7
40305.6100.432.8
ΔF44.221.4
1.2Q25199.254.427.3
30210.463.730.3
35226.370.531.2
40239.971.629.8
ΔF40.717.2