Research Article
Effect of Blade Outlet Angle on Radial Force of Marine Magnetic Drive Pump
Table 4
Amplitude of frequency domain and maximum fluctuation of radial resultant force on the blades.
| Flow | Model | Main frequency amplitude (N) | Maximum fluctuation amplitude (%) | Amplitude difference (%) |
| 0.8Q | 25 | 14.7 | 0.1890 | 0.0657 | 30 | 16.8 | 0.2065 | 35 | 18.9 | 0.2346 | 40 | 20.4 | 0.2547 |
| 1.0Q | 25 | 10.5 | 0.1680 | 0.0562 | 30 | 12.2 | 0.1346 | 35 | 14.6 | 0.1631 | 40 | 16.3 | 0.2242 |
| 1.2Q | 25 | 5.4 | 0.0623 | 0.0445 | 30 | 6.5 | 0.0910 | 35 | 7.3 | 0.0986 | 40 | 7.9 | 0.1068 |
|
|