Comparison of actual decay rates with those computed from FFT.
| | Frequencies | 100 Hz | 200 Hz | 400 Hz | 650 Hz | 950 Hz |
| Trial 1 actual | 0.07500 | 0.03750 | 0.01875 | 0.01154 | 0.00750 | Trial 1 from FFT | 0.07499 | 0.03750 | 0.01875 | 0.01154 | 0.00750 | Trial 2 actual | 0.075 | 0.0375 | 0.01875 | 0.03462 | 0.0225 | Trial 2 from FFT | 0.0756 | 0.0376 | 0.0188 | 0.0346 | 0.0222 | Trial 3 actual | 0.075 | 0.0375 | 0.01875 | 0.04616 | 0.03 | Trial 3 from FFT | 0.0757 | 0.0377 | 0.0189 | 0.0496 | 0.0280 | Trial 4 actual | 0.15 | 0.075 | 0.01875 | 0.01154 | 0.0075 | Trial 4 from FFT | 0.1433 | 0.0741 | 0.0188 | 0.0115 | 0.0075 |
|
|