Parameters of the mixed-flow pump model.
| Parameters | Value |
| Design operating point | | Designed flow rate Qdes (m3/h) | 380 | Designed rated head H (m) | 6 | Rated speed n (r/min) | 1450 | Specific speed ns | 480 | Impeller | | Number of impeller blades Z | 4 | Width of the impeller b2 (mm) | 67.2 | Inlet diameter of the impeller D1 (mm) | 185.2 | Outlet diameter of the impeller D2 (mm) | 243.2 | Average inlet blade angle β1 (°) | 24.9 | Average outlet blade angle β2 (°) | 31.8 | Tip clearance of blade t (mm) | 0.2 mm, 0.5 mm, 0.8 mm, and 1.1 mm | Diffuser | | Number of guide vane blades Zd | 7 | Inlet diameter D3 (mm) | 266.6 | Outlet diameter D4 (mm) | 281.8 | Average inlet blade angle α3 (°) | 45.6 | Average outlet blade angle α4 (°) | 86.5 | Pipe system | | Inlet diameter of the impeller Din (mm) | 200 | Outlet diameter of the impeller Dout (mm) | 250 |
|
|