Maximum acceleration reduction percentage in the regular and irregular 10-story models.
| Roof acceleration reduction % | 1-damper | 2-damper | 4-damper | Record | Near-field | Far-field | Near-field | Near-field | Far-field | Near-field |
| Regular 10-story | 28 | 36 | 46 | 46 | 46 | 44 | L-shaped 10-story | 27.72 | 32.04 | 40.02 | 45.54 | 45.54 | 43.56 | U-shaped 10-story | 29.96 | 38.52 | 49.22 | 49.22 | 49.22 | 47.08 |
|
|