Research Article

Experimental Study of Reinforcing Broken Gangues by Colloid Cement Slurry

Table 1

Data of colloid cement without uniaxial compressive strength.

AgeNumberStrength (MPa)Longitudinal strain (%)Elastic modulus (GPa)

7A1-16.90710.6877ā€”
A1-210.50410.73561.1866
B1-110.07100.69421.3766
B1-210.05540.45661.7840
C1-115.73200.95102.0016
C1-216.81280.88792.5621
14A2-115.77830.74692.1862
A2-218.98490.68573.0946
B2-115.75810.93712.0306
B2-216.09190.73382.3040
C2-116.32671.00402.2067
C2-216.54360.97052.1510
21A3-121.85460.84462.9703
A3-225.03560.76303.3304
B3-117.71481.17402.2601
B3-217.98771.19312.2901
C3-118.46451.02172.3318
C3-218.54070.97002.3780
28A4-124.05300.86603.2201
A4-227.36931.06403.1979
B4-127.79231.02423.3211
B4-224.76820.86893.1243
C4-125.02890.78263.3112
C4-225.15920.83203.0455