Research Article
Robust Assignment of Natural Frequencies and Antiresonances in Vibrating Systems through Dynamic Structural Modification
Table 9
Test-case 2: original and modified systems without and with robustness: percentage variation of the second antiresonance frequency of h12(jω).
| Percentual variations (%) [Δm5; Δ ] | Original system Δωz,2 (%) | Mod. nonrobust (method [22]) Δωz,2 (%) | Mod. robust (proposed method) Δωz,2 (%) |
| [−25; −25] | 0.04 | −0.35 | −0.27 | [+25; −25] | −9.24 | −7.35 | −5.76 | [−25; +25] | 6.21 | 4.68 | 3.77 | [+25; +25] | −0.03 | 0.30 | 0.24 | max (Δωz,2(%)) | 6.21 | 4.68 | 3.77 | min (Δωz,2(%)) | −9.24 | −7.35 | −5.76 |
|
|