Research Article

Crack Detection in Plate-Like Structures Using Modal Strain Energy Method considering Various Boundary Conditions

Table 8

Damage capacity indicator for extended verification case.

Damage threshold (%)Mode 1Mode 2Mode 3Mode 4Modes 1, 2Modes 1, 2, 3Modes 1, 2, 3, 4

2094 (H)88 (H)72 (A)75 (A)94 (H)94 (H)94 (H)
3094 (H)84 (H)56 (A)53 (A)91 (H)88 (H)88 (H)
4094 (H)69 (A)44 (L)41 (L)88 (H)75 (A)75 (A)
5094 (H)56 (A)41 (L)38 (L)69 (A)69 (A)69 (A)
6056 (A)50 (A)38 (L)31 (L)56 (A)56 (A)56 (A)
7050 (A)47 (L)31 (L)22 (L)50 (A)50 (A)53 (A)