Research Article

Steady Wind Load on External Surface and Its Effect on Wind-Induced Response for a 200 m High Natural-Draught Cooling Tower

Table 4

Cd of each harmonic component.

Specification curveDrag coefficient of each harmonic componentCD
Cd-a0Cd-a1Cd-a2Cd-a3Cd-a4Cd-a5Cd-a6Cd-a7

China-with rib0.000.410.000.000.000.000.000.000.41
China-without rib0.000.390.000.000.000.000.000.000.39
VGB-K1.00.000.660.000.000.000.000.000.000.66
VGB-K1.10.000.640.000.000.000.000.000.000.64
VGB-K1.20.000.600.000.000.000.000.000.000.60
VGB-K1.30.000.560.000.000.000.000.000.000.56
VGB-K1.50.000.490.000.000.000.000.000.000.49

VGB-K1.60.000.460.000.000.000.000.000.000.46