Clinical Study

Pulsed Wave Doppler Ultrasound Is Useful to Assess Vasomotor Response in Patients with Multiple System Atrophy and Well Correlated with Tilt Table Study

Figure 3

The correlation analysis of hemodynamic variables between SVR and the tilt table study. (a) The HR elevation upon SVR correlated positively with the HR elevation upon head-up tilt ( 𝑟 = 0 . 5 2 0 , 𝑃 = 0 . 0 0 5 ) but (b) negatively with the SBP drop from supine to tilt ( 𝑟 = 0 . 4 1 4 , 𝑃 = 0 . 0 2 9 ). The SVR latency demonstrated a positive correlation with (c) the SBP drop and (d) MAP drop after tilting up ( 𝑟 = 0 . 4 8 6 , 𝑃 = 0 . 0 0 9 and 𝑟 = 0 . 5 , 𝑃 = 0 . 0 0 7 , resp.). Note: SVR: sympathetic vasomotor response; HR: heart rate; SBP: systolic blood pressure; MAP: mean arterial pressure.
548529.fig.003a
(a)
548529.fig.003b
(b)
548529.fig.003c
(c)
548529.fig.003d
(d)