The Scientific World Journal / 2013 / Article / Tab 3 / Research Article
Aerodynamic Analysis of Cup Anemometers Performance: The Stationary Harmonic Response Table 3 Calibration coefficients,
and
, measured for the rotors tested with Climatronics 100075 anemometer (see also Table
2 and Figure
2 ). The coefficient of determination,
, of the curve fittings, and the slope of the transfer function based on the rotation frequency,
(see expressions (
1 ) and (
2 )), have also been included.
Conical cups Rotor
[m/pulse]
[m/rev]
[m/s]
c-20/30 0.02021 0.60618 0.37096 0.99995 c-20/40 0.03177 0.95318 0.23328 0.99999 c-20/50 0.04186 1.25574 0.31148 0.99999 c-20/60 0.05180 1.55401 0.40091 0.99999 c-25/40 0.02963 0.88886 0.26760 0.99999 c-25/50 0.03932 1.17970 0.20786 0.99999 c-25/60 0.04961 1.48829 0.24245 0.99999 c-25/80 0.06964 2.08928 0.39438 0.99999 c-25/100 0.08952 2.68552 0.53685 0.99999 c-30/40 0.02861 0.85818 0.09551 0.99995 c-30/50 0.03861 1.15844 0.19606 0.99999 c-30/60 0.04850 1.45505 0.14823 0.99998 c-30/80 0.06836 2.05089 0.25403 1.00000 c-30/100 0.08697 2.60900 0.38253 0.99998 c-30/120 0.10738 3.22145 0.49053 0.99999 c-35/50 0.03720 1.11603 0.19081 0.99999 c-35/60 0.04719 1.41582 0.15354 0.99999 c-35/80 0.06827 2.04818 0.18132 0.99998 c-35/100 0.08737 2.62111 0.22168 0.99999 c-35/120 0.10742 3.22259 0.34171 0.99999 c-40/50 0.03539 1.06166 0.13714 0.99999 c-40/60 0.04586 1.37587 0.16652 0.99999 c-40/80 0.06663 1.99876 0.16932 0.99998 c-40/100 0.08668 2.60026 0.23292 0.99996 c-40/120 0.10638 3.19140 0.28805 0.99996 c-40/140 0.12639 3.79164 0.34162 0.99995 Elliptical cups Rotor
[m/pulse]
[m/rev]
[m/s]
a-27/60 0.05221 1.56617 0.19932 0.99999 a-30/60 0.05306 1.59167 0.23224 0.99998 a-35/60 0.05412 1.62361 0.21593 0.99998 Porous cups Rotor
[m/pulse]
[m/rev]
[m/s]
h-09/60 0.05445 1.63352 0.31414 0.99999 h-19/60 0.06579 1.97376 0.54539 0.99998 h-24/60 0.11763 3.52881 0.31563 0.99998