Research Article

Approximate Single-Diode Photovoltaic Model for Efficient I-V Characteristics Estimation

Table 2

Relative errors of the calculated at various irradiance levels.

Module (W/m2) (°C)Relative error
ASDM PSIMPVsystVillalva et al. [21]

SQ150-PC 200256.34%0.51% 2.11% 1.51%
400253.29% 2.81% 0.30% 2.99%
600251.79% 3.60% 0.89% 2.68%
800251.18% 3.33% 0.29% 1.18%
1000250.59% 3.32% 0.00% 0.00%

KC200GT 20025 1.93% 1.31% 0.39% 0.39%
400250.39% 2.90% 1.93% 1.93%
600250.00% 4.16% 1.15% 1.15%
800250.00% 5.48% 0.38% 0.38%
1000250.38% 6.81% 0.00% 0.00%