Research Article

Efficient and Accurate Optimal Linear Phase FIR Filter Design Using Opposition-Based Harmony Search Algorithm

Table 9

Other comparative results of performance parameters of all algorithms for the FIR BP filter of order 20.

AlgorithmFIR BP filter of order 20
Maximum, average stop band ripple (normalized)Transition width (normalized)Execution time
for 100 cycles

PM0.07609, 0.0760170.0875
RGA0.02885, 0.0168550.09456.3827
PSO0.02504, 0.0158930.10094.6850
DE0.02350, 0.0151250.09874.9832
OHS0.01828, 0.014080.09884.7156