Clinical Study

The Value of Routine Polymerase Chain Reaction Analysis of Intraocular Fluid Specimens in the Diagnosis of Infectious Posterior Uveitis

Table 6

Estimated sensitivity, specificity, positive predictive value, and negative predictive value for each pathogen tested and broken down into AC and vitreous samples.

Sample numberTrue +veFalse +veTrue −veFalse −veSensSpecPPVNPV

CMV1546945%11%7448%75%91%99%99%91%
 AC 451329%00%3169%12%93%100%100%97%
 V 1065653%11%4341%66%90%98%98%88%
 NS 3267%00%133%00%
VZV1481510%21%12685%53%75%98%88%96%
 AC4312%00%3991%37%25%100%100%93%
 V1021414%22%8482%22%88%98%88%98%
 NS300%00%3100%00%
TOXO150128%00%13489%43%75%100%100%97%
 AC4512%00%4396%12%50%100%100%98%
 V1021111%00%8886%33%79%100%100%97%
 NS300%00%3100%00%
MTB4312%00%3991%37%25%100%100%93%
 AC2015%00%1680%315%25%100%100%84%
 V2200%00%22100%00%0%100%
 NS100%00%1100%00%

Total4959720%31%37375%194%84%99%97%95%

AC: anterior chamber; V: vitreous; NS: not specified; Sens: sensitivity; Spec: specificity; PPV: positive predictive value; NPV: negative predictive value.
(1) Three patients had samples taken from an unknown site (not specified in the clinical notes).
(2) Simultaneous vitreous and aqueous sampling was performed on 4 patients.
(3) Two patients had repeat sampling (both were vitreous sample repeats).