Research Article
New Sensors and Techniques for the Structural Health Monitoring of Propulsion Systems
Table 1
Multiple 10ā000 rpm cycle test results.
| ā | Algorithm | Correct detection rate | False alarm rate | Accuracy | Area under ROC |
| 5% false alarm rate | Orca | 100% | 5% | 97.55% | 1.00 | IMS | 93% | 5% | 94.02% | 0.93 | OCSVM | 100% | 5% | 97.55% | 0.99 |
| 90% correct detection | Orca | 90% | 0.58% | 94.62% | 1.00 | IMS | 90% | 0.36% | 94.73% | 0.93 | OCSVM | 90% | 1.26% | 94.28% | 0.99 |
|
|