Research Article

Modeling and Assessment of Long Afterglow Decay Curves

Table 3

Calculated constants for the DIN luminescence standard for different grades from A to G, where the luminous intensity increases as the grade number goes from A to G. A double exponential equation was used for interpretation.

Terms (min) (min)

A0.15870.01623.713834.8572
B0.29340.03144.090739.0857
C1.04150.10043.568036.8189
D1.54530.20463.750333.6278
E2.59390.25703.908438.4057
F3.28690.33663.944837.8302
G4.36110.44393.811034.8920