Research Article
Optimization of Integrated Impeller Mixer via Radiotracer Experiments
Table 5
ANOVA results for radiotracer experiments.
| Factors | SS | d.o.f. | Mean square | %contribution | Prob > |
| (1) MRT (s) | | | | | | Type mixer | 661.95 | 1 | 661.95 | 70.19 | 0.0069 | Speed | 197.89 | 2 | 98.95 | 20.98 | 0.0476 | Clearance | 38.32 | 2 | 19.16 | 4.06 | 0.0314 | Time | 29.86 | 2 | 14.93 | 1.60 | 0.0338 | Std. deviation | 3.87 | | | | | -squared | 0.9524 | | | | | Mean | 140.47 | | | | |
| (2) (%) | | | | | | Type mixer | 301.95 | 1 | 301.95 | 71.68 | 0.0087 | Speed (rpm) | 79.16 | 2 | 39.58 | 18.79 | 0.0440 | Clearance | 20.34 | 2 | 10.17 | 4.83 | 0.0337 | Time | 131.39 | 2 | 6.59 | 3.13 | 0.0419 | Std. deviation | 2.76 | | | | | -squared | 0.9448 | | | | | Mean | 10.53 | | | | |
|
|