ANOVA results for radiotracer experiments.

FactorsSSd.o.f.Mean square%contributionProb >

(1) MRT (s)
 Type mixer661.951661.9570.190.0069
 Speed197.89298.9520.980.0476
 Clearance38.32219.164.060.0314
 Time29.86214.931.600.0338
 Std. deviation3.87
-squared 0.9524
 Mean140.47

(2) (%)
 Type mixer301.951301.9571.680.0087
 Speed (rpm)79.16239.5818.790.0440
 Clearance 20.34210.174.830.0337
 Time 131.3926.593.130.0419
 Std. deviation2.76
-squared 0.9448