Research Article

Analysis of Heat Transfers inside Counterflow Plate Heat Exchanger Augmented by an Auxiliary Fluid Flow

Table 3

Critical parameters for (*) and (**) as functions of and , respectively ( .

Case with (19)Case with (21)
/

0.050.250.250.120.40.466−5.3420.146
0.050.50.250.120.40.466−5.3420.146
2.050.250.250.120.750.194−15.930.058
2.050.50.250.120.750.194−15.930.058

/
0.120.250.250.050.40.466−6.8650.114
0.120.50.250.050.40.466−6.8650.114
2.050.250.250.050.750.194−15.930.05
2.050.50.250.050.750.194−15.930.05

( ) The parameters that produce are and ( for the case given by (19) while ( for the case given by (21)
(**) The parameters that produce are and ( for the case given by (19) while ( for case given by (21).