Research Article
Calculation of Reaction Forces in the Boiler Supports Using the Method of Equivalent Stiffness of Membrane Wall
Table 3
Elasticity constants and wall thickness of equivalent orthotropic plate for membrane walls of “Milano” boiler.
| Membrane wall (position) | , mm | , GPa | , GPa | , GPa | | , GPa | , GPa | , GPa | |
| 5, 7, 17, 19, 22 | 23.48 | 76.492 | 1.367 | 4.915 | 0.005361 | 454.159 | 8.064 | 29.095 | 0.005327 | 6 | 23.48 | 76.492 | 1.367 | 4.915 | 0.005361 | 454.159 | 8.023 | 29.025 | 0.005300 | 13 | 23.48 | 76.492 | 1.367 | 4.915 | 0.005361 | 454.159 | 8.203 | 29.336 | 0.005419 | 16 | 23.48 | 76.492 | 1.367 | 4.915 | 0.005361 | 454.159 | 7.690 | 28.439 | 0.005080 | 18 | 20.40 | 88.592 | 3.880 | 8.722 | 0.013138 | 442.956 | 9.583 | 31.199 | 0.006490 |
|
|