Research Article

Calculation of Reaction Forces in the Boiler Supports Using the Method of Equivalent Stiffness of Membrane Wall

Table 3

Elasticity constants and wall thickness of equivalent orthotropic plate for membrane walls of “Milano” boiler.

Membrane wall (position) ,
mm
, GPa , GPa , GPa , GPa , GPa , GPa

5, 7, 17, 19, 2223.4876.4921.3674.9150.005361454.1598.06429.0950.005327
623.4876.4921.3674.9150.005361454.1598.02329.0250.005300
1323.4876.4921.3674.9150.005361454.1598.20329.3360.005419
1623.4876.4921.3674.9150.005361454.1597.69028.4390.005080
1820.4088.5923.8808.7220.013138442.9569.58331.1990.006490