Research Article

Effect of the Key Mixture Parameters on Shrinkage of Reactive Powder Concrete

Table 3

Weights of the constituents of 27 RPC mixtures (for 1 m3).

Mix IDw/b ratioCement (kg)Silica fume (%)Silica fume (kg)Water (kg)Fiber (kg)SP (%)SP (kg)Sand (kg)Effective w/b ratio considering water in SP

M10.151000151501731573.55419770.183
M20.151000202001801573.55438980.182
M30.151000252501881573.55448180.182
M40.151100151651901573.55458270.182
M50.151100202201981573.55477390.182
M60.151100252752061573.55496520.182
M70.151200151802071573.55496760.182
M80.151200202402161573.55515810.182
M90.151200253002251573.55534860.182
M100.1751000151502011572239450.193
M110.1751000202002101572248650.193
M120.1751000252502191572257840.193
M130.1751100151652211571.5198060.188
M140.1751100202202311571.5207180.189
M150.1751100252752411571.5216300.189
M160.1751200151802421571.5216540.189
M170.1751200202402521571.5225580.189
M180.1751200253002631571.5234620.189
M190.201000151502301571.5178860.213
M200.201000202002401571.5188030.214
M210.201000252502501571.5197190.214
M220.201100151652531571137410.209
M230.201100202202641571136500.209
M240.201100252752751571145590.209
M250.201200151802761571145830.209
M260.201200202402881571144840.209
M270.201200253003001571153850.209