Research Article

Extension of Weighted Sum of Gray Gas Data to Mathematical Simulation of Radiative Heat Transfer in a Boiler with Gas-Soot Media

Table 6

Comparison of the calculated steam generation rates with measured data.

Load (%)10075

Fuel flow rate (Ton/h)30.522.9
Measured in the site (Ton/h)503375
Calculated data (Ton/h)492.5401.58
Discrepancy (%)āˆ’2.08āˆ’6.9