Journals
Publish with us
Publishing partnerships
About us
Blog
The Scientific World Journal
Journal overview
For authors
For reviewers
For editors
Table of Contents
Special Issues
The Scientific World Journal
/
2014
/
Article
/
Tab 2
/
Research Article
Percutaneous Compression Plate versus Dynamic Hip Screw for Treatment of Intertrochanteric Hip Fractures: A Meta-Analyse of Five Randomized Controlled Trials
Table 2
Meta-analysis results of complications comparing PCCP with DHS.
Complications
Group (
n
)
Studies (
n
)
Overall effect
PCCP
DHS
Effect estimate
95% CI
P
value
Respiratory
102
109
2
0.70
0.28~1.75
0.45
Pulmonary embolism
102
109
2
0.52
0.09~2.93
0.46
Cardiovascular event
102
109
2
0.80
0.33~1.92
0.61
Cerebrovascular accident
102
109
2
0.17
0.02~1.42
0.10
DVT
102
109
2
0.33
0.08~1.44
0.14
Superficial wound infection
102
109
2
0.35
0.04~3.41
0.37
DVT: deep-vein thrombosis; PCCP: percutaneous compression plate; DHS: dynamic hip screw; CI: confidence interval.