Review Article
A Perspective Review on Numerical Simulations of Hemodynamics in Aortic Dissection
Table 2
Tear configurations used in numerical simulations for aortic dissection.
| Number | Tear shape | Tear diameter (mm) | True lumen diameter (mm) | False lumen diameter (mm) | Number of tears | Reference |
| 1 | Elliptical | Long axis: 22–26 Short axis: 10–15 | 7.0–12.5 | 16.5–21.0 | 1 (reentry tear) | [28] | 2 | Nearly circular | 37 | 48 | 62 | 1 (entry tear) | [20] | 3 | Spherical | 10 | 20 | 20 | 2 (1 entry, 1 reentry) | [19] | 4 | Elliptical | Long axis: 13 Short axis: 10 | 40–80 | 40–80 | 2 (1 entry, 1 reentry) | [16] | 5 | Elliptical | Long axis: 6 Short axis: 3 | — | — | 1 (entry tear) | [18] | 6 | Elliptical | Long axis: 9–11 Short axis: 16–23 | — | — | 1 (entry tear) | [7] | 7 | Elliptical | Long axis: 18–33 Short axis: 9–36 | — | — | 1 (entry tear) | [47] |
|
|