Research Article

Structural Safety Analysis Based on Seismic Service Conditions for Butterfly Valves in a Nuclear Power Plant

Table 3

Results of structural analysis based on static analysis for Grade D of the KEPIC MFA.

ā€‰Max. stress (MPa)Safety factor

Normal pressure574.1
Reverse pressure1351.7