Research Article
Lymphocyte Oxidative Stress/Genotoxic Effects Are Related to Serum IgG and IgA Levels in Coke Oven Workers
Table 3
Dose-response relationship with the levels of 1-OHP with immunoglobins.
| 1-OHP level | IgG (g/L) | IgA (g/L) | IgM (g/L) | IgE (IU/mL) | β | β | β | β | (95% CI) | (95% CI) | (95% CI) | (95% CI) | | | | |
| Control group | −0.109 | −0.472 | −0.051 | −0.067 | (−0.359–0.130) | (−0.438–0.296) | (−0.445–0.283) | (−0.941–0.518) | 0.353 | <0.001 | 0.658 | 0.565 |
| Exposed group | −0.312 | −0.538 | −0.062 | −0.071 | (−0.3455–0.176) | (−0.463–0.211) | (−0.903–0.465) | (−0.233–0.098) | <0.001 | <0.001 | 0.592 | 0.420 |
|
|