Study | Publication year | Method |
Instrument |
Socket type |
Soft liner type |
Measure |
Measurement interface |
Static | Dynamic |
|
Sanders et al. [34] | 1992 | | ✓ | Custom designed transducers, strain gauge | PTB | Pelite liner | Normal and shear stresses | Skin/soft tissue |
|
Sanders et al. [33] | 1993 | | ✓ | Custom designed transducers | PTB | Pelite liner | Normal and shear stresses | Skin/soft tissue |
|
Zhang et al. [36] | 1996 | ✓ | | Simplified model | PTB | Unknown | Frictional action | Skin/soft tissue |
|
Zhang et al. [45] | 1998 | ✓ | ✓ | Force transducer mounting | PTB TSB | Pelite liner | Stress | Skin/soft tissue |
|
Sanders et al. [51] | 2000 | | ✓ | Force transducer mounting | PTB | Five-ply sock | Pressures and shear stresses | Skin/soft tissue |
|
Goh et al. [52] | 2003 | | ✓ | Force transducer mounting | PCast | Silicone liner | Pressure | Skin/soft tissue |
|
Lin et al. [37] |
2004 | ✓ | | FEM | PTB | Unknown | Pressure | soft tissue/liner |
|
Jia et al. [16] | 2004 | | ✓ | Vicon motion system, FEM | PTB | Unknown | Pressure | Bone-soft tissue |
|
Lee et al. [53] | 2004 | ✓ | | MRI, FEM, Vicon system | PTB | Unknown | Pressure | Soft tissue/socket |
|
Sanders et al. [54] | 2005 | | ✓ | Force transducer | PTB TSB | Neoprene and latex sleeves | Interface stress | Soft tissue/socket |
|
Lee and Zhang [42] |
2007 | ✓ | | Push gauge, FEA | PTB | Pelite liner | Pain threshold pressure | Skin/soft tissue |
|
Portnoy et al. [44] | 2008 | ✓ | | MRI, FEA, pressure sensor | PTB | Unknown | Mechanical conditions, pressure/shear strains | Muscle/soft tissue |
|
Wolf et al. [55] | 2009 | | ✓ | 3D gait analysis, pressure sensor, Vicon motion system | TSB | Silicone liner | Pressure | Residual limb/socket interface |
|
Abu Osman et al. [56] |
2010 | ✓ | ✓ | Transducer, sensor | PTB | No liner | Pressure and shear stress | Residual limb/socket interface |
|
Dumbleton et al. [57] | 2009 | | ✓ | Tekscan F-Scan | PTB | Silicone liner, pelite liner | Pressure | Residual limb/socket interface |
|
Boutwell et al. [58] | 2012 | | ✓ | Motion analysis sensor | PTB TSB | Silicone liner | Gait and pressure | Residual limb/liner interface |
|
Kobayashi et al. [13] | 2012 | | ✓ | Biaxial MEMS tilt sensors, force transducer unit | Unknown | Unknown | Reaction moment | Below the socket |
|
Kobayashi et al. [14] | 2013 | | ✓ | Biaxial MEMS tilt sensors, force transducer unit | Unknown | Unknown | Reaction moment | Below the socket |
|
Boone et al. [11] | 2013 | | ✓ | Biaxial MEMS tilt sensors, force transducer unit | Unknown | Unknown | Reaction moment | Below the socket |
|