Research Article
Effect of Flow Rate of Side-Type Orifice Intake on Withdrawn Water Temperature
Table 1
Withdrawn water temperature with different submerse depths and discharges.
| Depth (cm) | March | May | October | 1.0 L/s | 1.7 L/s | 2.5 L/s | 1.0 L/s | 1.7 L/s | 2.5 L/s | 1.0 L/s | 1.7 L/s | 2.5 L/s |
| First intake (15) | 12.46 | 12.52 | 12.58 | 21.48 | 21.4 | 21.24 | 22.09 | 21.93 | 21.82 | Second intake (23) | 11.85 | 12.02 | 12.09 | 18.51 | 18.46 | 18.2 | 21.91 | 21.86 | 21.75 | Third intake (31) | 11.22 | 11.36 | 11.37 | 15.58 | 15.98 | 16.17 | 21.25 | 21.08 | 20.92 | Fourth intake (39) | 10.53 | 10.54 | 10.66 | 12.77 | 12.94 | 12.96 | 19.26 | 19.14 | 18.91 |
|
|