Assigning Robust Default Values in Building Performance Simulation Software for Improved Decision-Making in the Initial Stages of Building Design

Table 2

Simulation conditions.

valueOuter wall: 0.25 W/m2K (concrete block and brickwork)
Ground floor: 0.15 W/m2K, roof: 0.15 W/m2K
Window: 1.96 W/m2K (double glazing)

WindowDouble glazing, value: 1.96 W/m2K, total solar transmission (SHGC): 0.70, direct solar transmission: 0.62, and light transmission: 0.74

Window shadingBlind with high reflectivity slats
Solar setpoint for cases 1, 5, 9, 13: 120 W/m2
Maximum allowable glare index for the other cases: 22.0

Internal heatHuman: 0.1 person/m2, 123 W/person, office equipment: 11.8 W/m2

Lighting3.3 W/m2—100 lux
Target illuminance: 400 lx

Mechanical ventilation10 L/s-person

HeatingNatural gas (carbon emission factor: 0.195 kg CO2/kWh)
Heating system CoP: 0.830
Schedule: 5:00–19:00 in weekday: on, all other periods: on by set-back temp.
Setpoint temperature: 22°C, set-back temperature: 12°C

CoolingElectricity from grid (carbon emission factor: 0.685 kg CO2/kWh)
Cooling system CoP: 1.670
Schedule: 5:00–19:00 in weekday: on, all other periods: off
Setpoint temperature: 26°C