Research Article
An Analysis of Transient Overvoltages during the Energization of Electric Ship Propulsion Systems
Table 1
The series parameters for the MV cable line.
| | Core 1 | Core 2 | Core 3 | | R [Ω/m] | L [H/m] | R [Ω/m] | L [H/m] | R [Ω/m] | L [H/m] |
| Core 1 | 0.750 ⋅ | 1.96 ⋅ | 0.673 ⋅ 10−3 | 1.48 ⋅ 10−3 | 0.663 ⋅ 10−3 | 1.21 ⋅ 10−3 | Core 2 | 0.673 ⋅ 10−3 | 1.48 ⋅ 10−3 | 0.771 ⋅ | 1.88 ⋅ | 0.711 ⋅ 10−3 | 1.46 ⋅ 10−3 | Core 3 | 0.663 ⋅ 10−3 | 1.21 ⋅ 10−3 | 0.711 ⋅ 10−3 | 1.46 ⋅ 10−3 | 0.828 ⋅ | 1.93 ⋅ | Screen 1 | 0.682 ⋅ 10−3 | 1.81 ⋅ 10−3 | 0.673 ⋅ 10−3 | 1.48 ⋅ 10−3 | 0.663 ⋅ 10−3 | 1.21 ⋅ 10−3 | Screen 2 | 0.673 ⋅ 10−3 | 1.48 ⋅ 10−3 | 0.703 ⋅ 10−3 | 1.72 ⋅ 10−3 | 0.711 ⋅ 10−3 | 1.46 ⋅ 10−3 | Screen 3 | 0.663 ⋅ 10−3 | 1.21 ⋅ 10−3 | 0.711 ⋅ 10−3 | 1.46 ⋅ 10−3 | 0.760 ⋅ 10−3 | 1.77 ⋅ 10−3 |
| | Screen 1 | Screen 2 | Screen 3 | | R [Ω/m] | L [H/m] | R [Ω/m] | L [H/m] | R [Ω/m] | L [H/m] |
| Core 1 | 0.682 ⋅ 10−3 | 1.81 ⋅ 10−3 | 0.673 ⋅ 10−3 | 1.48 ⋅ 10−3 | 0.663 ⋅ 10−3 | 1.21 ⋅ 10−3 | Core 2 | 0.673 ⋅ 10−3 | 1.48 ⋅ 10−3 | 0.703 ⋅ 10−3 | 1.72 ⋅ 10−3 | 0.711 ⋅ 10−3 | 1.46 ⋅ 10−3 | Core 3 | 0.663 ⋅ 10−3 | 1.21 ⋅ 10−3 | 0.711 ⋅ 10−3 | 1.46 ⋅ 10−3 | 0.760 ⋅ 10−3 | 1.77 ⋅ 10−3 | Screen 1 | 0.801 ⋅ | 1.81 ⋅ | 0.673 ⋅ 10−3 | 1.48 ⋅ 10−3 | 0.663 ⋅ 10−3 | 1.21 ⋅ 10−3 | Screen 2 | 0.673 ⋅ 10−3 | 1.48 ⋅ 10−3 | 0.821 ⋅ | 1.72 ⋅ | 0.711 ⋅ 10−3 | 1.46 ⋅ 10−3 | Screen 3 | 0.663 ⋅ 10−3 | 1.21 ⋅ 10−3 | 0.711 ⋅ 10−3 | 1.46 ⋅ 10−3 | 0.879 ⋅ | 1.77 ⋅ |
|
|