Research Article
Optimal Pipe Size Design for Looped Irrigation Water Supply System Using Harmony Search: Saemangeum Project Area
Table 8
Analysis results of the optimal and initial hydraulic designs (three cases).
|
Target water supply network | ā | Nodal pressure head (m) | Pipe velocity (m/s) | ā | Min. | Max. | Avg. | Var. | Min. | Max. | Avg. | Var. |
| Loop type (plan 1) | Initial plan | 17.65 | 31.66 | 23.04 | 13.95 | 0.01 | 1.92 | 0.97 | 0.16 | Optimal design | 10.00 | 29.08 | 15.36 | 23.68 | 0.02 | 2.46 | 1.18 | 0.29 |
| Branch type (plan 2) | Initial plan | 10.45 | 31.66 | 21.24 | 23.55 | 0.09 | 2.22 | 1.11 | 0.09 | Optimal design | 10.00 | 29.08 | 14.28 | 20.63 | 0.15 | 2.40 | 1.08 | 0.30 |
| Pump type (plan 3) | Initial plan | 0.5 | 30.79 | 25.17 | 10.63 | 0.07 | 1.89 | 0.95 | 0.06 | Optimal design | 10.00 | 30.79 | 16.14 | 29.26 | 0.22 | 2.49 | 1.36 | 0.25 |
|
|