The Scientific World Journal / 2015 / Article / Tab 2

Research Article

On the Stator Slot Geometry of a Cable Wound Generator for Hydrokinetic Energy Conversion

Table 2

Stator slot geometry of the reference machine compared to the suggested improved geometry.

Parameter Reference New design

Slot opening 4 mm 4 mm
Slot width () 8  mm 7.6 mm
Cable diameter 7 mm 7 mm
Waist width () 6 mm 6.1 mm
Waist factor 0.75 0.8
Cable to cable () 2 mm 0.8 mm
Cable to air gap () 5.5 mm 1.3 mm
Cable to stator () 0.5 mm 0.3 mm
Slot depth 58 mm 47.6 mm

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.