Parameter
Reference
New design
Slot opening
4 mm
4 mm
Slot width ()
8 mm
7.6 mm
Cable diameter
7 mm
7 mm
Waist width ()
6 mm
6.1 mm
Waist factor
0.75
0.8
Cable to cable ()
2 mm
0.8 mm
Cable to air gap ()
5.5 mm
1.3 mm
Cable to stator ()
0.5 mm
0.3 mm
Slot depth
58 mm
47.6 mm
We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.