On the Stator Slot Geometry of a Cable Wound Generator for Hydrokinetic Energy Conversion
Table 3
Reference machine performance at its nominal operating point compared with the suggested improved design.
Parameter
Reference
New design
Efficiency
86.4%
87.0%
B in stator tooth
1.69 T
1.57 T
Hysteresis losses in teeth
0.149 kW
0.128 kW
Eddy current losses in teeth
0.037 kW
0.032 kW
Total losses
0.785 kW
0.748 kW
Load angle
Stator weight
598 kg
532 kg
We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.