Research Article

Impact of Cross-Tie Properties on the Modal Behavior of Cable Networks on Cable-Stayed Bridges

Table 1

Comparison of modal properties of a twin-cable network with damped flexible or rigid cross-tie at .

ModeDamped flexible cross-tie Rigid cross-tie
( kN/m,  kN·s/m) (, )
(Hz) (%)Mode shape (Hz) (%)Mode shape
AnalyticalFEAAnalyticalFEA

11.461.460.500.50GM, in-phase1.460.50GM, in-phase
21.631.633.343.35GM, out-of-phase2.180.33LM, RS
32.912.910.250.25GM, in-phase2.910.25GM, in-phase
43.023.022.492.49GM, out-of-phase4.370.17LM, RS
54.374.370.170.17GM, in-phase4.370.17GM, in-phase
64.374.370.170.17GM, out-of-phase4.370.17LM, LS
75.835.820.130.13GM, in-phase5.830.13GM, in-phase
85.885.871.191.19GM, out-of-phase6.560.11LM, RS
97.287.270.100.10GM, in-phase7.280.10GM, in-phase
107.337.311.031.03GM, out-of-phase8.740.08LM, RS

GM: global mode, LM: local mode, LS: left segment mode, and RS: right segment mode.