Optimal Siting and Sizing of Multiple DG Units for the Enhancement of Voltage Profile and Loss Minimization in Transmission Systems Using Nature Inspired Algorithms

Table 6


AlgorithmPSOGSAHybrid

DG type

5 DGs’ WK bus
FIT3.0962175.1143914.1773732.361394.27682.3646211.7644374.27681.800886
(MW)3.9485076.483545.0232423.0471115.4742963.0293912.2345555.4742962.291437
(MVAR)17.086727.9145421.4565912.9490223.6079613.043349.82336623.607969.988834
VD0.0101270.0976330.497416
solar (MW)35.1623734.5751735.2153435.7124844.3306745.38128
%   solar12.3551512.2001312.4260212.6014415.6424416.01315
solar (MVAR)16.0183713.5555215.410415.4364715.410416.63139
%   solar12.6928410.741312.2110912.2317512.2110913.1786

3 DGs’ WK bus
FIT4.2643065.8831975.4379682.8942934.237522.9934512.3196834.3356882.489634
(MW)4.3302556.4423376.2527523.6878365.4117553.8204552.9184935.4694293.154463
(MVAR)21.9027731.0618526.9366516.035523.4340616.5629212.9804123.6806413.85381
VD
solar (MW)24.1154524.1079621.308721.2673528.3561227.09767
%   solar8.5093338.5066927.5189497.50435610.005699.561632
solar (MVAR)10.671527.6893199.3238429.6590020.09695310.82097
%   solar8.4560376.0929637.3881487.6537267.2971198.574461

3 DGs’ LSF
FIT4.2120655.8831975.3973362.819444.2511882.9895522.2123573.9214142.450767
(MW)4.2513286.4423376.2064263.5699995.4371773.8028942.7767695.4845663.046115
(MVAR)21.719731.0618526.7841915.699423.4817616.5853612.3833823.7106313.84625
VD1.0038740.9494430.99394
solar (MW)24.1154524.1079621.34121.2902631.0047623.9273
%   solar8.5093337.6893197.5303457.51244210.940288.442944
solar (MVAR)10.671528.5066929.3133169.6622299.2089645.900359
%   solar8.4560376.0929637.3798077.6562837.2971194.675403

4 DGs’ WK bus
FIT3.5900474.3101234.2043492.6924994.2046492.5740011.8208074.3101232.163678
(MW)3.9430145.4778714.6081113.4585675.3601183.2225652.2840125.4778712.728538
(MVAR)17.7251923.679920.9792314.8199623.2860714.3427910.0846323.679912.08686
VD0.7954060.0452330.897432
solar (MW)28.2749928.1382928.206631.8257542.0758434.21096
%   solar9.9621769.9288259.95292811.2299814.846812.07162
solar (MVAR)12.1544910.6556612.3843712.4250612.1544913.52161
%   solar9.6311348.4434759.8132899.845539.63113410.71443

4 DGs’ LSF
FIT3.5769754.6514194.1888042.5797674.2099862.5675461.9252614.3099612.001535
(MW)3.9245375.8310844.5840433.2986125.367233.2272932.4294935.4774742.53162
(MVAR)17.6769625.9913620.9214514.2524823.3144814.3387310.7490523.6791111.15468
VD0.7921660.0207340.89499
solar (MW)28.2749928.1382928.1909231.8427338.8361438.21796
%   solar9.9770599.9288259.94739611.2359713.7036513.48552
solar (MVAR)13.0100110.6556712.3856712.3937812.1544912.44819
%   solar10.309048.4434759.8143169.8207459.6311349.863862