Research Article
Parallel Jacobi EVD Methods on Integrated Circuits
Table 2
Comparison of 4 × 4 and 10 × 10 Jacobi EVD arrays.
| | PE array size | Full CORDIC 4 × 4 | -CORDIC 4 × 4 | Full CORDIC 10 × 10 | -CORDIC 10 × 10 |
| Area | Combinational | 0.847 mm2 | 0.296 mm2 | 5.143 mm2 | 1.829 mm2 | Noncombinational | 0.390 mm2 | 0.123 mm2 | 2.306 mm2 | 0.833 mm2 | Total | 1.237 mm2 | 0.419 mm2 | 7.449 mm2 | 2.662 mm2 |
| Power | Cell | 62.283 mW | 18.239 mW | 388.379 mW | 123.215 mW | Net | 0.465 mW | 0.433 mW | 2.993 mW | 2.678 mW | Leakage | 11.909 mW | 3.765 mW | 86.136 mW | 23.966 mW | Total | 74.657 mW | 22.437 mW | 477.508 mW | 149.859 mW |
| Timing | Critical | 4.454 ns | 1.213 ns | 4.286 ns | 2.247 ns | Frequency | 224.5 MHz | 824.4 MHz | 233.3 MHz | 445 MHz |
|
|