Technical parameters of the coilable mast.
| Parameter | Value |
| Coiling radius () | 75 mm |
| Radius of longeron | 1 mm |
| Radius of batten | 0.65 mm |
| Batten pitch length () | 95 mm |
| Height between hinges (coiled zone) () | 3 mm |
| Material of hinge | Aluminum alloy Young’s modulus: 70.6 GPa; Poisson’s ratio: 0.33 |
| Material of longeron and batten | Ti-Ni alloy Young’s modulus: 83 GPa; Poisson’s ratio: 0.31 |
|
|