Research Article

Research on the Simulation Method for Equivalent Stiffness of Bolted Connection Thin Plate Structures

Table 2

First 4th order natural frequency of the structure for the linearized equivalent of the bolt.

Order1234

Natural frequency 23.08281.378129.38239.11