LSSVM comprehensive test results.
| Kernel function | Motor status | Number of test samples | Number of correct classifications | Number of misclassifications | Correct rate | Total correct rate |
| Linear | Normal | 25 | 24 | 1 | 96% | 98.67% | Uniform demagnetization | 25 | 25 | 0 | 100% | Partial demagnetization | 25 | 25 | 0 | 100% |
| Polynomial | Normal | 25 | 23 | 2 | 92% | 92% | Uniform demagnetization | 25 | 24 | 1 | 96% | Partial demagnetization | 25 | 22 | 3 | 88% |