Research Article

Wrist EMG Monitoring Using Neural Networks Techniques

Table 4

Error-values and percentage of correct classification for WL parameter.

PerformanceExtensionFlexionPronationSupinationTotal

MSE0.080.020.180.090.09
NMSE0.060.030.120.110.08
MAE0.090.080.260.120.14
Min abs error0.070.060.200.160.12
Max abs error0.130.090.960.800.49
R0.920.950.910.910.92
Percent correct (%)87.5689.0381.7284.6785.74