Research Article

Reduced-Precision Redundancy on FPGAs

Table 4

Mathematical ( ) versus experimental ( ) threshold values for RPR FIR filter designs with several different reduced-precision bit widths ( ). The mean ( ) and standard deviation ( ) values for the signal are also shown.

% Change

7 0.1597 0.1049 0.05380 0.008500
6 0.3106 0.1844 0.08365 0.01563
5 0.6046 0.3182 0.1431 0.02891
4 1.2212 0.5849 0.2453 0.0562
3 2.3871 0.9222 0.3659 0.09465