Research Article

An Analytic Analysis of the Diffusive-Heat-Flow Equation for Different Magnetic Field Profiles for a Single Magnetic Nanoparticle

1Department of Electrical Engineering, Faculty of Engineering, Tel-Aviv University, 69978 Tel-Aviv, Israel
2Department of Biomedical Engineering, Faculty of Engineering, Tel-Aviv University, 69978 Tel-Aviv, Israel

Received 10 February 2012; Revised 1 June 2012; Accepted 4 June 2012

Academic Editor: Yuval Garini

Copyright © 2012 Brenda Dana and Israel Gannot. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

This study analytically analyzes the changes in the temperature profile of a homogenous and isotropic medium having the same thermal parameters as a muscular tissue, due to the heat released by a single magnetic nanoparticle (MNP) to its surroundings when subject to different magnetic field profiles. Exploring the temperature behavior of a heated MNP can be very useful predicting the temperature increment of it immediate surroundings. Therefore, selecting the most effective magnetic field profile (MFP) in order to reach the necessary temperature for cancer therapy is crucial in hyperthermia treatments. In order to find the temperature profile caused by the heated MNP immobilized inside a homogenous medium, the 3D diffusive-heat-flow equation (DHFE) was solved for three different types of boundary conditions (BCs). The change in the BC is caused by the different MF profiles (MFP), which are analyzed in this article. The analytic expressions are suitable for describing the transient temperature response of the medium for each case. The analysis showed that the maximum temperature increment surrounding the MNP can be achieved by radiating periodic magnetic pulses (PMPs) on it, making this MFP more effective than the conventional cosine profile.

1. Introduction

Magnetic Hyperthermia (MH) is one of many approaches currently being tested for cancer therapy [13]. The goal of this approach is to specifically heat the regions containing the cancerous cells by means of the magnetic losses caused by the physical properties of the magnetic nanoparticles (MNPs) when being exposed to an external magnetic field (MF).

The MNPs that are often used in MH, are usually made of ferromagnetic or ferrimagnetic materials which strongly react to the externally applied MF [4]. This magnetic reaction is converted by the two dominant relaxation mechanisms, the Néel mechanism and Brownian mechanism, into power dissipation or heat [1, 4].

The eddy currents losses contribution may be neglected due to the low electrical conductivity that characterizes ferro- or ferrimagnetic materials and due to the small particle radius [59].

Fannin et al. [10] pointed out that for small enough particles, the anisotropy energy barrier, 𝐸𝑎, may become so small, that thermal energy fluctuations can overcome it and spontaneous reverse the magnetization of a particle from one easy direction to the other, even in the absence of an applied field. The time it takes for a spontaneously fluctuation to reverse the magnetization after overcoming the energy barrier is characterized by a time constant, referred to as the Néel relaxation time, or 𝜏𝑁. The probability of such a transition is proportional to exp(𝜎), where 𝜎 is the ratio of anisotropy energy to thermal energy or (𝐸𝑎/𝑘𝐵𝑇) [11].

The other distinct mechanism, by which the magnetization of MNPs may relax after an applied field has been removed, is the physical rotational Brownian motion of the particle immobilized inside a medium. When a magnetic field is applied to MNPs, they rotate and progressively align with the magnetic field due to the torque generated by the interaction of the magnetic field with the magnetization [12]. The time associated for an MNP to align with a small external magnetic field is given by the Brownian relaxation time, 𝜏𝐵 [13].

Because these relaxation mechanisms happen simultaneously, they both contribute to the total magnetization and the heat losses and their total influences can be express by an effective relaxation time, 𝜏𝑒, which is a combination of 𝜏𝑁 and 𝜏𝐵 [1416].

The two relevant mechanisms to change the magnetization of magnetic particles in an external field are given in Figure 1.

fig1
Figure 1: (a) Néel rotation of magnetization inside a fixed magnetic particle due to the spontaneously reversing the magnetization from one easy direction to the other (the particle does not rotate); (b) Brownian rotation of an MNP due to the rotation of the torque generated by the interaction of the magnetic field with the magnetization (the particle rotates as a whole) [17].

Moreover, our interests in MNPs as heat sources derive from the fact that they are vastly used as MRI agents [17] and their controllable size, ranging from few nanometers to tens of nanometers [18]. This means that the MNP size is smaller than or as same as that of a protein (5–50 nm), a virus (20–450 nm) or a gene (2 nm wide and 10–100 nm long) [11], which enables them to penetrate through the leaky pathological vasculature into the tumor interstitial easily reaching any cell of interest in the body including cancerous cells [19].

In addition, the MNPs can be attached to a specific type of cancerous cells causing a controllable elevation of temperature in them with almost no effects on healthy cells [20, 21]. By selectively heating the cancerous cells to a temperature ranging from 42 to 46°C, one can damage the tumors without causing vast harm to the healthy surrounding tissue [17, 19, 22].

Furthermore, in order to ensure that the treatment is biologically noninvasive and thermally tolerated for extended period of time, an experimentally measured tolerable limit of induced heating by an alternative MF was conducted defining a limit to the product of the MF strength (𝐻) and the frequency (𝑓) of the MF (e.g., 𝐻𝑓4.85108 A/m·s [23] or a less rigid criterion 𝐻𝑓5109 A/m·s [24]).

Due to the MNPs submicron length size, the conventional approach to heat conduction problems using macroscopic empirical laws such as Fourier’s law or Joule’s law of heat generation requires justification and even breakdown when the length scale of the system is comparable to the carrier mean free path or when the time scale of the physical process is smaller than the relaxation time of the heat carriers [25]. In this case, transport of heat carriers must be treated using the Boltzmann transport equation as Chen et al. pointed out [26].

Chen [27] suggested that heat is transported by carriers comprising of electrons, phonons, and photons. In dielectric materials, the heat conduction is dominated by phonons, in pure metals predominantly by electrons, and in impure metals or alloys by both phonons and electrons [27, 28]. Therefore, the mean free path of the heat carriers, for an MNP with a Fe core is approximately 0.8 nm [29, 30] and for a biological tissue 0.5 nm [26, 31, 32] allowing the conventional approach to be used for particles having a radius bigger than 10 nm.

Consequently, the temperature gradient caused by the release of the magnetic energy which an MNP absorbs to its immediate surroundings can be found analytically when applying Fourier transforms (FTs) to the DHFE [33] as Shih et al. [34] and Yuan et al. [35] suggested. Using this technique, Liu and Xu [36] analyzed the influences that a sinusoidal heat flux source placed on the skin surface have on the temperature inside it, and Tjahjono [37] analytically analyzed the heating temperature of a slab embedded with gold NPs due to a constant magnetic flux.

By analytically solving the DHFE for different boundary conditions, one can easily describe the dependence of the solution on each parameter composing it, such as the radius of the MNP, the frequency of the MF, and the material properties [38]. This allows us to optimize the solution for better performances, reaching the highest temperature elevation under specific constrains, for example the radius of the MNP. Moreover, when exploring the solution analytically, other parameters and their influence may be observed more clearly, which are usually neglected, or not explored (e.g., the MFP and its effects on the temperature gradient).

Until recently, the MFP was poorly analyzed in context of hyperthermia treatments and how it influences the temperature distribution concerning biological materials and tissues surrounding MNPs. Previous work focused on exploring the influences of different magnetic profiles on biological tissues. These studies were mostly experimental and did not focus on the MNPs contribution to the temperature change when exposed to different types of magnetic field profiles [3943].

Recently, a numerical simulation model based on the Landau-Lifshitz-Gilbert equation was created for simulating MNPs ensembles when exposed to an incident square wave [44], as opposed to the usual sine wave. This work showed an increase in the normalized heat released by MNPs by at least 50%, as well as a more constant heating efficiency over the spectrum of particle anisotropies due to the infinite number of harmonics contained in an ideal square wave with the possibility of much greater improvement depending on the magnetic anisotropies, volumes, and angles to the incident radiation. However, Morgan and Victora [44] did not elaborate on the temperature dependencies on space and time near the MNP surface, but mostly focused on the dependencies between the angle of the incident wave relative to the anisotropy axis of the MNPs and the magnitude of the normalized output power released from them.

Therefore, the primary aim of this paper is to explore the transient analysis of the changes in temperature (from the steady state temperature 𝑇𝑏=310.15°K), as a function of the external MFP applied to a single MNP. By doing so, one can select the most efficient MFP that may improve the efficiency of MH treatments allowing the MF strength and the frequency reductions in order to meet the requirement 𝐻𝑓4.85108 A/m·s [23].

The aims of this paper are as follows:(i) To construct a theoretical model of the magnetic losses for the three different MF profiles studied in this article as follows:(1) Case 1—a cosine profile [18, 37],(2) Case 2—a PMP [45, 46],(3) Case 3—a discontinuous cosine profile.(ii)To explore the maximal temperature elevation and the rate of the temperature change near the MNP’s surface and into the tissue-like surrounding it for each of the above cases. (iii)To investigate who the core radius influences the maximal rate of the temperature change and the maximal temperature value, in order to find the optimal core radius that should be used for each of the above cases [5, 47].(iv)To study the effective confining heat depth (ECHD), symbolized as 𝛿 (see Figure 2), where the temperature elevation has a significant influence for each of the above cases.

135708.fig.002
Figure 2: The control volume where the conductive analysis is preformed. 𝑞𝑠 is the constant heat flux released from the MNP after absorbing the magnetic energy and δ is the thickness of the penetration region [37].

2. Methods

In this study, we analytically model the transient temperature field (TTF) produced by a single MNP inside a homogenous and uniform medium having the same thermal parameters as a cancerous muscle cell. The analysis for each of the three MFPs mentioned in Section 1 is presented, after solving the DHFE inside the medium surrounding the MNP with the proper BC corresponding to its specific MFP.

In order to simplify the solution of DHFE that gave us the TTF and the temperature rate change due to the magnetic losses, some assumptions were made:(a)The properties of the surrounding medium are constant and homogeneous having the same thermal properties as the macroscopic-scale muscular tissue [48]. (b)The temperature on the surface of the MNP is uniform.(c)There is a negligible emission and evaporation.(d)There are no “thermally significant” blood vessels near the zone of interest therefore the perfusion is negligible.(e)The metabolic-heat generation is neglected.

2.1. The Thermodynamic Analysis

The TTF originating from the surface of a single MNP can be found after solving the 3D DHFE in the homogenous medium surrounding it [39]. The general DHFE can be written in spherical coordinates (due to the problem’s symmetry) as follows: 𝑘𝑚2𝑇𝑚(𝑟,𝑡)=𝜌𝑚𝑐𝑚𝜕𝑇𝑚(𝑟,𝑡),𝜕𝑡(1) where 𝜌𝑚 (kg m−3) is the mass density, 𝑐𝑚 (J kg−1°C−1) the specific heat, and 𝑘𝑚 (Wm−1°C−1) the thermal conductivity of the phantom tissue.

This equation was also used by Keblinski et al. [38] and Govorov et al. [49] for solving nanoscale heat problems.

The general BC for this heat problem is given as follows: 𝑘𝑚𝑇𝑚||(𝑟,𝑡)𝑟=𝑎=𝑞𝑠(𝑡),(2) where 𝑎: is the radius of the MNP in meters and 𝑞𝑠(𝑡) (Wm−2) is the heat flux.

The DHFE is valid if the mean free path of the heat carrier phonon or electron is smaller than the characteristic feature size as mentioned in Section 1. For amorphous solids and liquids, due to lack of crystalline, the mean free path is very short and of the order of atomic distances. Consequently, the heat flow in cells can be well described by the diffusive heat equation, even when nanoscopic length scales are involved [31].

Based on the above considerations, we evaluate the temperature field arising from continuous heating of a single particle by solving the heat equation (1) in the region outside the solid sphere surrounding the MNP where there are no heat sources, using a constant heat-flux-boundary condition at the particle surface, caused by the magnetic losses inside the MNP. The constant heat flux from the MNP’s surface becomes heat input to the medium which is then stored within the volumetric penetration depth region as shown in Figure 2.

After solving (1) and (2) (see the detailed formulations in Appendix A (A.1)–(A.12)), the temperature elevation inside the medium surrounding the MNP can be expressed using (A.12) as follows: Δ𝑇𝑚(𝑟,𝑡)=𝜃(𝑅,𝑡)𝑘𝑚𝑟𝛼𝑚=𝜙(𝑅,𝑡)𝑞𝑠(𝑡)𝑘𝑚𝑟𝛼𝑚,(3) where symbolizes the convolution between two functions, 𝑅=1/𝛼𝑚𝑟 and 𝛼𝑚=𝑘𝑚/𝜌𝑚𝑐𝑚.

In order to analytically calculate (3), the general expression of 𝑞𝑠(𝑡) must be found for each case, which depends on 𝐻(𝑡) (Am−1), the magnetic field, and on 𝑀(𝑡) (Am−1), the magnetization.

When a linear and isotropy material is assumed, the relation between 𝑀(𝑡) and 𝐻(𝑡) in the frequency domain (using FTs) may be described by the magnetic susceptibility [5] 𝑀(𝜔)=𝑑𝑡𝜒𝑡𝑒𝑖𝜔𝑡𝑑𝑡𝐻(𝑡)𝑒𝑖𝜔𝑡=𝜒(𝜔)𝐻(𝜔).(4) The magnetic susceptibility 𝜒(𝜔) in the frequency domain can be expressed as [4] 𝜒𝜒(𝜔)=01+𝑖𝜔𝜏𝑒=𝜙𝜇0𝑀𝑠2𝑣𝑝3𝑘𝐵𝑇11+𝑖𝜔𝜏𝑒,(5) where 𝜒0 is the static susceptibility, 𝜏𝑒=𝜏Neel||𝜏Brown is the effective relaxation time given by Fannin [14], 𝜙 is the volume fraction solid [4], 𝑣𝑝 the particle volume, 𝜇0 the vacuum permeability, 𝑘𝐵 is the Boltzmann constant, and 𝑀𝑠 is the magnetic saturation.

Moreover, in order to calculate the total heat generated by a single MNP caused by the conversion of the absorbed magnetic energy to heat inside a linear ferromagnetic medium, we must introduce Poynting’s theorem for small electric fields and neglecting ohmic losses [5, 6] as follows: 𝑆out(𝑡)=𝑑𝜔𝑑𝜔𝐻(𝜔)𝐻(𝜔)𝜔𝜇0Im(𝜇(𝜔))𝑒𝑖(𝜔𝜔)𝑡𝜕𝑈(𝑡)𝜕𝑡=𝑃Loss(𝑡)𝜕𝑈(𝑡),𝜕𝑡(6) where 𝑆out(𝑡) represents the energy flowing out through the boundary surfaces of the volume per unit time, 𝐻(𝜔) is the conjugate of 𝐻(𝜔),𝜇0=4𝜋107 (Vs/Am) is the vacuum permeability, 𝜇(𝜔)=𝜇𝑟(𝜔)𝑖𝜇im(𝜔)=𝜇0(1+𝜒(𝜔)) is the complex magnetic permeability [5, 6], Im() is the imaginary part of 𝜇(𝜔), 𝜕𝑈(𝑡)/𝜕𝑡 is the time rate change of the effective electromagnetic energy density given by (7), and 𝑃Loss(𝑡) represents the conversion of the magnetic energy into heat not counting conductive losses. It is worth mentioning that only the imaginary part of the complex permeability is causing heat losses, and 𝜕𝑈(𝑡)/𝜕𝑡 can be found using [5, 6] as follows: 𝐻𝜕𝐵=𝜕𝑡𝑑𝜔𝑑𝜔𝐻(𝜔)𝐻(𝜔)𝜔𝜇0Im𝜇(𝜔)𝑒𝑖(𝜔𝜔)𝑡+𝜇0𝜕2𝜕𝑡𝑑𝜔𝑑𝜔𝑑𝐻(𝜔)𝐻(𝜔)𝜔𝑑𝜔𝜇(𝜔)×𝑒𝑖(𝜔𝜔)𝑡=𝑃Loss(𝑡)+𝜕𝑈(𝑡),𝜕𝑡(7) where 𝜇(𝜔) is the conjugate of 𝜇(𝜔).

Next, the explicit analytic expressions for the temperature gradient profile from the equilibrium tempertaure, Δ𝑇𝑚(𝑟,𝑡) and 𝜕𝑇𝑚(𝑟,𝑡)/𝜕𝑡 are deduced for three different BC derived from the three MFPs mentioned earlier in Section 1.

2.2. The Analytic Expressions of the TTF for Three Different MFPs

Case 1 (a cosine profile). The magnetic field has a cosine profile so 𝐻𝜔(𝑡)=𝐴cos0𝑡.(8) Taking the inverse FT of (A.19) deduced in Appendix A using (A.13)–(A.19), one can find that 𝜃(𝑅,𝑡) can be written in this case as 𝜃(𝑅,𝑡)=𝑎𝜇0𝐴2𝜔06𝜔0𝜒0𝜏𝜔1+0𝜏2𝑎𝑅0𝑒𝑖2𝜔0𝑡2𝑅0𝑖2𝜔0+1exp𝑖2𝜔0𝑅+𝑎𝑅0𝑒𝑖2𝜔0𝑡2𝑅02𝜔0𝑖+1exp𝑖2𝜔0𝑅,+1(9) where 𝜃(𝑅,𝑡) is a function in the complex domain, therefore the temperature profile has a magnitude and phase as often occurs in many problems of physics or engineering such as theory of heat conduction, particularly when nonsteady heat conduction is concerned [50, 51]. Moreover, (9) is related to the TTF by (3).
Sometimes, the derivative of the temperature profile, or the rate of the change in the temperature surrounding the MNP is taken in consideration in order to verify that the treatment is safe for inducing controlled MH [47, 52]. For Case 1, this equals 𝜕𝜃(𝑅,𝑡)𝜕𝑡=𝑖𝜔0𝑎𝜇0𝐴2𝜔06𝜔0𝜒0𝜏𝜔1+0𝜏2𝑎𝑅0𝑒𝑖2𝜔0𝑡𝑅0𝑖2𝜔0+1exp𝑖2𝜔0𝑅𝑎𝑅0𝑒𝑖2𝜔0𝑡𝑅02𝜔0𝑖+1exp𝑖2𝜔0𝑅.(10)

Case 2 (a PMP). The magnetic field has a rectangular pulse shape profile with a period of 𝑇𝑠=2𝜋/𝜔0 and a pulse width of Δ, so 𝐻(𝑡)=2𝐴0𝑡Δ,𝐻(𝑡)=0Δ𝑡𝑇𝑠.(11) The amplitude of the pulse wave was chosen to be twice the amplitude of the cosine single in order to maintain the same peak-to-peak value, for this case and the previous one. For this case, the temperature elevation as a function of time can be expressed using the inverse FT of (A.25) found in Appendix A that was deduced using (A.20)–(A.25) to receive the following: =𝑎𝜃(𝑅,𝑡)34𝜇0𝐴2𝜔0𝜋2sin𝑚𝜋Δ/𝑇𝑠𝑚sin𝑛𝜋Δ𝑇𝑠𝑛𝜔0𝜒0𝜏1+𝑛𝜔02𝜏2𝑎𝑅0𝑒𝑖(𝑛+𝑚)𝜔0𝑡𝑅0𝑖(𝑛+𝑚)𝜔0+1exp𝑖(𝑛+𝑚)𝜔0𝑅+𝑎𝑅0𝑒𝑖(𝑛+𝑚)𝜔0𝑡𝑅0𝑖(𝑛+𝑚)𝜔0+1exp𝑖(𝑛+𝑚)𝜔0𝑅+𝑎𝑅0𝑒𝑖(𝑚𝑛)𝜔0𝑡𝑅0𝑖(𝑚𝑛)𝜔0+1exp𝑖(𝑚𝑛)𝜔0𝑅+𝑎𝑅0𝑒𝑖(𝑚𝑛)𝜔0𝑡𝑅0𝑖(𝑚𝑛)𝜔0+1exp𝑖(𝑚𝑛)𝜔0𝑅+𝑎34𝜔0𝜇0𝐴2Δ𝜋𝑇𝑠sin𝑛𝜋Δ𝑇𝑠𝑛𝜔0𝜒0𝜏1+𝑛𝜔02𝜏2×𝑎𝑅0𝑒𝑖𝑛𝜔0𝑡𝑅0𝑖𝑛𝜔0+1exp𝑖𝑛𝜔0𝑅+𝑎𝑅0𝑒𝑖𝑛𝜔0𝑡𝑅0𝑖𝑛𝜔0+1exp𝑖𝑛𝜔0𝑅.(12) Again, (12) is related to the TTF by (3).

As for Case 1, we can calculate the rate of the change in the temperature surrounding the MNP and receive the following: 𝜕𝜃(𝑅,𝑡)𝜕𝑡=𝑖𝜔20𝑎34𝜇0𝐴2𝜋2sin𝑚𝜋Δ/𝑇𝑠𝑚×sin𝑛𝜋Δ𝑇𝑠𝑛𝜔0𝜒0𝜏1+𝑛𝜔02𝜏2(𝑛+𝑚)𝑎𝑅0𝑒𝑖(𝑛+𝑚)𝜔0𝑡𝑅0𝑖(𝑛+𝑚)𝜔0+1×exp𝑖(𝑛+𝑚)𝜔0𝑅(𝑛+𝑚)𝑎𝑅0𝑒𝑖(𝑛+𝑚)𝜔0𝑡𝑅0𝑖(𝑛+𝑚)𝜔0+1×exp𝑖(𝑛+𝑚)𝜔0𝑅+(𝑚𝑛)𝑎𝑅0𝑒𝑖(𝑚𝑛)𝜔0𝑡𝑅0𝑖(𝑚𝑛)𝜔0+1×exp𝑖(𝑚𝑛)𝜔0𝑅(𝑚𝑛)𝑎𝑅0𝑒𝑖(𝑚𝑛)𝜔0𝑡𝑅0𝑖(𝑚𝑛)𝜔0+1×exp𝑖(𝑚𝑛)𝜔0𝑅+𝑖𝜔20𝑎34𝜇0𝐴2Δ𝜋𝑇𝑠sin𝑛𝜋Δ𝑇𝑠𝑛2𝜔0𝜒0𝜏1+𝑛𝜔02𝜏2×𝑎𝑅0𝑒𝑖𝑛𝜔0𝑡𝑅0𝑖𝑛𝜔0+1exp𝑖𝑛𝜔0𝑅𝑎𝑅0𝑒𝑖𝑛𝜔0𝑡𝑅0𝑖𝑛𝜔0+1exp𝑖𝑛𝜔0𝑅.(13)

Case 3 (a discontinuous cosine profile). The magnetic field has a periodic discontinuous cosine profile with a time constant of 𝑇𝑠=2𝜋/𝜔1 and a pulse width of Δ, so 𝐻𝜔(𝑡)=𝐴cos0𝑡0𝑡Δ,𝐻(𝑡)=0Δ𝑡𝑇𝑠𝜔0𝜔1.(14) For this third case, the temperature elevation as a function of time can be expressed using the inverse FT of (A.35) found in Appendix A that was deduced using (A.30)–(A.35) to receive: =𝑎𝜃(𝑅,𝑡)3𝜇0𝐴𝑇𝑠2𝑎𝑅0×𝜔sin(Δ/2)0+𝑚𝜔1𝜔0+𝑚𝜔1+𝜔sin(Δ/2)0𝑚𝜔1𝜔0𝑚𝜔1×𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+𝜔sin(Δ/2)0𝑛𝜔1𝜔0𝑛𝜔1𝑛𝜔12𝜒0𝜏1+𝑛𝜔12𝜏2×𝑒𝑖(𝑛+𝑚)𝜔1𝑡𝑅0𝑖(𝑛+𝑚)𝜔1+1×exp𝑖(𝑛+𝑚)𝜔1𝑅+𝑒𝑖(𝑛+𝑚)𝜔1𝑡𝑅0𝑖(𝑛+𝑚)𝜔1+1×exp𝑖(𝑛+𝑚)𝜔1𝑅+𝑒𝑖(𝑚𝑛)𝜔1𝑡𝑅0𝑖(𝑚𝑛)𝜔1+1×exp𝑖(𝑚𝑛)𝜔1𝑅+𝑒𝑖(𝑚𝑛)𝜔1𝑡𝑅0𝑖(𝑚𝑛)𝜔1+1×exp𝑖(𝑚𝑛)𝜔1𝑅.(15) Again, (15) is related to the TTF by (3).

As for Cases 1 and 2, we can calculate the rate of the change in the temperature surrounding the MNP to receive the following: 𝜕𝜃(𝑅,𝑡)𝜕𝑡=𝑖𝜔1𝑎3𝜇0𝐴𝑇𝑠2×𝜔sin(Δ/2)0+𝑚𝜔1𝜔0+𝑚𝜔1+𝜔sin(Δ/2)0𝑚𝜔1𝜔0𝑚𝜔1×𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+(𝜔sinΔ/2)0𝑛𝜔1𝜔0𝑛𝜔1𝑛𝜔12𝜒0𝜏1+𝑛𝜔12𝜏2×(𝑛+𝑚)𝑎𝑅0𝑒𝑖(𝑛+𝑚)𝜔1𝑡𝑅0𝑖(𝑛+𝑚)𝜔1+1×exp𝑖(𝑛+𝑚)𝜔1𝑅(𝑛+𝑚)𝑎𝑅0𝑒𝑖(𝑛+𝑚)𝜔1𝑡𝑅0𝑖(𝑛+𝑚)𝜔1+1×exp𝑖(𝑛+𝑚)𝜔1𝑅+(𝑚𝑛)𝑎𝑅0𝑒𝑖(𝑚𝑛)𝜔1𝑡𝑅0𝑖(𝑚𝑛)𝜔1+1×exp𝑖(𝑚𝑛)𝜔1𝑅(𝑚𝑛)𝑎𝑅0𝑒𝑖(𝑚𝑛)𝜔1𝑡𝑅0𝑖(𝑚𝑛)𝜔1+1×exp𝑖(𝑚𝑛)𝜔1𝑅.(16) For Cases 2 and 3, there is a limitation regarding the MFS and the frequency in order for the MH treatment to be safe (see (A.30) and (A.39)). Moreover, for frequencies lower than 10 MHz, there is essentially no attenuation of the MFS within muscle-equivalent materials, limiting the maximal harmonic frequency to 10 MHz [16].

In conclusion, (9)–(16) can be used to predict the TTP and the special temperature profile for a single-MNP subject to three different magnetic field profiles and using the same equations we can also explore the influence that the core radius has on the temperature profile estimating the ECHD for each case.

2.3. The Simulations Parameters

The mathematical expressions of the TTP were simulated using MATLAB and COMSOL (COMSOL results can be seen in Appendix B) for a single MNP immobilized inside a uniform and isotropic phantom medium having the same biological thermal properties as a muscular tissue [48] and are summarized in Table 1. These assumptions were made in order to simplify the theoretical calculations.

tab1
Table 1: Thermal tissue properties for the phantom muscle cell at a temperature of 310.15 K [48].

The thermal parameters are considered to be constant with temperature and space as will be latter proven. Moreover, the magnetic parameters of the MNP were measured at 𝑇𝑏=310.15°K based on the findings of Fannin [14] and are summed up in Table 2.

tab2
Table 2: The magnetic parameters of the MNP [14].

The external magnetic field strength (MFS) for all three cases, was chosen as 8.8 kAm−1 and the MF frequency as 𝑓0=400KHz. These values are based on previous works made by Kettering et al. [52], Hergt et al. [53], and Hilger et al. [54].

For all three profiles mentioned in this section, the simulations were plotted for 0𝑟𝑎10 nm and 0𝑡5μs, where 𝑟 is the distance from the center of the MNP and 𝑎 its radius. The upper value for distance simulation was chosen accordantly to the thickness of the cell membrane thatis about 5–10 nm [5557] and damaging it can cause the destruction of the cell [58]. The upper time value was chosen so several cycles of the magnetic field could be simulated and plotted.

For all the simulations the volume fraction solid was defined as 𝜙=0.032. This value is been justified in Section 4.

In Section 3, as already mentioned in Section 1, the maximal temperature elevation and the temperature change rate near the MNP’s surface and into the tissue surrounding it, are simulated. Moreover, the influence the core radius has on the maximal temperature change rate and on the maximal temperature elevation was also explored, in order to find the optimal value that must be used for each case as suggested by Rosensweig [4] and Kappiyoor et al. [47]. Furthermore, the ECHD that is defined by the point the temperature reaches 𝑒1 of the maximal value, has also been explored for each case, defining the confining heat region and can be compared with the thickness of a cell membrane which varies between 3–10 nm [5356].

3. Results

The mathematical expressions of the TTP were simulated in this section, using MATLAB, for a single MNP immobilized inside a uniform and isotropic phantom medium having the same biological thermal properties as a muscular tissue (Table 1). Moreover, the MNP’s magnetic parameters are summarized in Table 2.

For Case 1, the mathematical expression of the temporal and spatial temperature increment, (9), is presented in Figure 3 for 𝑇𝑠=2.5μs.

135708.fig.003
Figure 3: The temperature profile for a cosine MFP plotted as a function of time and as a function of the observation point located at a distance, 𝑟, from the surface of the MNP; 𝑟 ranging from 0 nm to 10 nm for a core radius of 10 nm.

It can be seen from Figure 3 that the temperature changes periodically with a time period of 1.25 μs that is equivalent to a frequency oscillation of 800 kHz, which is twice the frequency of the external applied MF, as predicted by (9). This can be explained by the multiplication of the magnetic field and the magnetic induction, both being a function of 𝑓0 or 𝜔0.

Moreover, the temperature increment reached its maximum value after 0 μs, reaching Δ𝑇max=2.1 n°K on the surface of the MNP. As expected, the hottest spots are on the surface of the MNP, and as the point of view gets further from the surface the temperature declines as (9) predicted. This value causes only a low-temperature gradient in the thermal properties of the surrounding medium therefore, the thermal parameters of the phantom cell can be considered constants, as assumed.

According to Figure 3, the temperature profile has a “DC” level that can be found from calculating the first term of (9) making the temperature increment to be always higher than the initial temperature as expected, because the magnetic losses inside the MNP irradiate heat to the medium surrounding it, at all times [59, 60].

Furthermore, at a distance of 12 nm apart from the MNP’s surface the temperature maximal value equals 0.8 n°K that is equivalent to 𝑒1 of the absolute maximal value, defining the ECHD or 𝛿=12 nm.

In order to have a unique quantity to be compared with each case and does not depend on time, we averaged the TTP over one cycle. In Case 1, the averaged value over one time period equals 0.55 n°K.

Next, we explored the maximal temperature rise rate as a function of the core radius using (9) and (10) receiving the data in Figure 4.

135708.fig.004
Figure 4: The maximal temperature rise rate and the maximal temperature for a cosine MFP plotted as a function of the core radius; 𝑎 ranging from 5 nm to 15 nm, where the observation points are on the surface of the MNP.

As can be seen from Figure 4, the maximal temperature rate change equals 0.011°Ks−1 and the maximal temperature rise equals 4.7 n°K, both received for a core radius of 9.3 nm. The temperature rate rise and the maximal temperature are considerably small, due to the relaxation time that depends on the volume of the particle making this MFP to be safe to use for MH treatments [47]. For radii larger or smaller than 9.3 nm, the magnetic heat dissipation start to decrease as the magnetic relaxation time gets bigger or smaller, respectively, reducing the denominator or numerator in (9) and (10).

Equations (9) and (10) enable us to understand that the changes in the temperature depend on many parameters such as, the magnetic field strength, the magnetic field frequency, the magnetic properties of the material, and the core radius. Consequently, in order to optimize the heat losses we must select the most effective radius for a specific type of MNP.

For Case 2, the mathematical expression of the temporal and spatial temperature increment are plotted in Figure 5 for the summation of 25 indexes (not to exceed 10 MHz [16]) and Δ=0.2𝑇𝑠, where 𝑇𝑠=2.5μs.

135708.fig.005
Figure 5: The temperature rise for a periodic pulse-shaped MFP having a pulse width of 0.2𝑇𝑠 plotted as a function of the observation point located at a distance, 𝑟 from the surface of the MNP, 𝑟 ranging from 0 nm to 10 nm for a core radius of 10 nm, and the number of indexed summed is 25.

For convenience, Figure 5 describes the temperature profile for the first two cycles as given by (12). This equation shows that the characteristic behavior of the temperature repeats itself every 𝑇𝑠=2.5μs, that is, the cycle of the magnetic field, therefore one can limit the study to only a final number of cycles.

As can be seen from Figure 5, the temperature builds up very fast due to the steep elevation of the magnetic field caused by the Heaviside-shaped MP and reaches a maximal value of Δ𝑇max=8.8 n°K on the MNP’s surface after 0.45 μs. Then the temperature begins to drop after 0.1 μs from the time the MF was turned on reaching a minimal value of 6 n°K near the surface of the MNP. From that point on, the temperature profile temporal behavior is defined by the summation of the total numbers of harmonics composing the MF until the MF is turned off again as can be found from (12). Furthermore, the temperature reaches its maximum value close to the surface of the MNP and decreases with distance reaching a maximal value of 3 n°K, 12 nm apart from the MNP’s surface.

For this case, the maximal value is 4 times higher than the one received in Case 1, making it a preferable MFP to be used in MH as Morgan and Victora suggested [44].

Again, the thermal parameters can be considered constant and not dependent on temperature near the MNP’s surface because the temperature rise is less than 1°K.

From Figure 5, the ECHD can be found as 𝛿=12nm, which is the same as the value received in Case 1, meaning that the temperature decreases as fast as the cosine case and is confined to a specific area near the MNP’s surface.

Moreover, in order to have a unique quantity to be compared in each case that does not depend on time, we averaged the total temperature rise over one cycle. In this case the averaged temperature elevation was 1.3 n°K after been normalized to the time period. This value is about 2.4 times higher than the value received in Case 1, making this MFP a better candidate for MH treatments.

Next, we explored the maximal temperature rise rate as a function of the core radius. For Case 2, we can use (11) and (12) receiving the data in Figure 6.

135708.fig.006
Figure 6: The absolute maximal temperature rise rate and the maximal temperature for a periodic pulse-shaped MFP having a pulsed width of 0.2𝑇𝑠 plotted as a function of the core radius; 𝑎 ranging from 5 nm to 15 nm, the observation point are on the surface of the MNP, and the number of indexed summed is 25.

As seen from Figure 6, the absolute maximal temperature elevation equals 0.032 μ°K received for a core radius of 8.3 nm, and the maximal temperature derivative 1.01 °Ks−1 is received for a core radius of 8.2 nm. Because this MFP produces temperature changes that are too rapid to be safe for inducing MH [47], the radius that we chosen for a safer treatment is in consistence with Case 1 and equals 10 nm. Consequently, the NP size plays an important role in determining the amount of heating that an MFH treatment can provide as Kappiyoor et al. [47] already mentioned.

Again, the maximal temperature rate rise and the maximal temperature are considerably small due to the relaxation time that depends on the volume of the particle. For radii larger or smaller than 8.4 nm, the magnetic heat dissipation starts to decrease as the magnetic relaxation time gets bigger or smaller, respectively, due to its affect on the relaxation time, reducing the denominator or numerator in (11) and (12).

By comparing Case 2 to Case 1 we see that for the same MNP radius (10 nm) having the same magnetic material properties (given by Table 2), the maximal temperature rise received is about 4 times higher for Case 2 than in Case 1 and the maximal temperature derivative for this case is 40 times higher than Case 1, making the periodic pulse-shaped MFP a better magnetic field source for MH treatments.

For Case 3 the analytic expression for the TTP can be plotted for Δ=0.2𝑇𝑠 and 𝑇𝑠=15μs and are shown in Figure 7 for the summation of 25 indexes (not to exceed 10 MHz [16]). The cosine MF time period that multiplies the Heaviside function equals 2.5 μs, and is equivalent to a frequency of 400 KHz.

135708.fig.007
Figure 7: The temperature profile for a periodic discontinuous cosine MFP having a pulse width of 0.2𝑇𝑠 plotted as a function of time and as a function of the observation point located at a distance, 𝑟, from the surface of the MNP, 𝑟 ranging from 0 nm to 10 nm for a core radius of 10 nm, and the number of indexed summed is 25.

As Figure 7 shows, the changes in the temperature profile result from the MNP reaction to two different MFPs, the cosine profile and the periodic rectangular pulse profile. The last is responsible for switching on and off the MF.

The influence that the periodic rectangular-pulse-shaped MF has on the temperature gradient can be seen by the steep temperature elevation at the beginning and at the end of every cycle caused by the derivative of Heaviside function composing the magnetic flux density, 𝐵(𝑡), and the influence that the cosine MFP has on the temperature gradient can be seen as the cosine “ripple” that is added. This “ripple” has 3 peaks that are separated 1.25 μs apart, which is twice the cosine MF frequency received in Case 1. On the MNP surface, the maximal temperature gradient reaches Δ𝑇max=2.3 n°K after 2 ns from the time the MF was turned on, and repeats itself every 15 μs, which is equivalent to the time period of the signal. This value is higher than the value received for the cosine-shaped MF, but lower than the one received in Case 2. However, after the highest peak the maximal value of the cosine “ripple” reaches the same one as in the cosine case or 2.1 n°K as expected.

For this case, the ECHD equals 𝛿=12nm that is the same as for the other two cases where the temperature change reaches a value of 0.8 n°K. After 0.2 𝑇𝑠, the temperature elevation becomes insignificant as the MF is turned off.

Again, in order to have a unique quantity to be compared in each case that does not depend on time, we can average the total temperature rise over one cycle. In this case the average temperature elevation equals 0.235 n°K after we normalize it to the time period. This value is about 2.5 times lower than the value received in Case 1, making this MFP a less preferable candidate for MH treatments.

Next we explored the maximal temperature rise rate as a function of the core radius. For Case 3, we used (15) and (16) receiving the data in Figure 8.

135708.fig.008
Figure 8: The absolute maximal temperature rise rate and the maximal temperature rise for a periodic discontinuous cosine MFP having a pulse width a pulsed width of 0.2𝑇𝑠 plotted as a function of the core radius, 𝑎 ranging from 5 nm to 15 nm, the observation point are on the surface of the MNP, and the number of indexed summed is 25.

As seen from Figure 8, the absolute maximal temperature rate elevation equals 5.4 n°K received for a core radius of 9.2 nm. The maximal temperature derivative 0.024°Ks−1 is received for a core radius of 9.1 nm. Again, the maximal temperature rate rise and the maximal temperature are considerably small due to the relaxation time that depends on the volume of the particle. For radii larger or smaller than 9.2 nm, the magnetic heat dissipation starts to decrease as the magnetic relaxation time gets bigger or smaller, respectively, reducing the denominator or the numerator in (15) and (16).

By comparing Case 3 to Case 1 for a core radius of 10 nm and the same magnetic material properties (given by Table 2), the maximal temperature rise received for Case 3 is about two times higher than Case 1, and the maximal temperature derivative for this case is 2.2 times higher than Case 1. However, due to the long period for which the MF is turned off, and consequently the lower heat released from the MNP over one cycle, this MFP is less preferable than the cosine MFP, for MH treatments.

In order to make it easier to understand the differences between the three cases analyzed in this paper, Table 3 is added that summarizes the most significant parameters.

tab3
Table 3: Summary of the most significant parameters received from all the simulations.

Moreover, a summarizing figure, Figure 9, describing the temperature rise as a function of time is also added for a particle with a core radius of 10 nm when the observation point is on the MNP surface, in order to easily evaluate the differences in the three cases studied in this article.

135708.fig.009
Figure 9: The temperature rise profiles plotted as a function of time for a core radius of 10 nm and an observation point located on surface of the MNP, for all the cases explored in this paper Case 1 (red) the cosine MFP, Case 2 (green) the periodic pulse-shaped MFP with a duty cycle of 0.2 and 𝑁=25, Case 3 (blue) the periodic discontinuous cosine MFP with a duty cycle of 0.2 and 𝑁=25.

4. Discussion

An analytical analysis of the TTP was preformed for three MFPs. The mathematical models were received by solving the DHFE for different BC matching each MFP, using the FTs.

Major work have been done in the past to solve the DHFE equation for a cosine-MF source as can be found in [36, 37, 49, 59]. Keblinski et al. [38] found that a laser source having a constant power of 1.4108 W heating a single MNP with a radius of 65 nm can cause a temperature change of 0.06 K at the particle surface. Moreover, for a cosine-MF heat source the local temperature was found to be even lower, causing a maximum change in temperature of 0.1 m°K for a particle having a radius of 50 nm at a frequency of 2 MHZ [48]. Both results are negligible from the point of view of biological applications as expected.

However, Keblinski et al. [38] and others [4, 20] solved the DHFE equation only for a constant heat flux having the average power of a cosine-MF, without exploring the temperature temporal behavior. In addition, until now there has not been an explicit mathematical formulation that solves the DHFE equation for other periodic MFPs that can be used as radiation sources for MH treatments. Morgan and Victora [44] showed that the use of an incident square wave, as opposed to the usual sine wave, increases the normalized power heat by at least 50%, however this conclusion was based on calculating only the Poynting vector and not based the solving the DHFE in order to find the explicit temperature change.

In consequence to the above, we should explore the influences that different magnetic irradiation profiles have on the induced temperature gradients inside tumor cells, for the same physical and thermal MNP’s parameters in order to verify what Morgan and Victora [44] suggested. Furthermore, optimizing the heat power is of great importance from biological point of view. A typical cell having a diameter ranging from 2–10 μm [61] can uptake a maximal quantity of anionic MNPs, that varies between 2.8105 and 7.2106 per cell, consequently limiting the total amount of magnetic material per cell. Moreover, high concentration of MNPs with different types of coatings can cause a toxic reaction to the central nervous system [62] or may cause cellular perturbations [63] therefore, it is important to reduce the MNP’s concentration. Nevertheless, reaching these quantities in vivo proves to be a very difficult task all types of cancerous cells [64, 65]. Hence, one must optimize other parameters such as, the profile of the MF in order to use lower magnetic concentration in order to reach the same temperature gradient values.

Consequently, this paper focuses on the influences that three different MFPs have on the temperature surrounding a single MNP, as mentioned in Section 1, when being exposed to it, analytically proving to be the most effective one in causing the highest temperature rise, using the same magnetic and thermal parameters.

For all three cases, the MATLAB (in Section 3) and COMSOL (in Appendix B) simulations results showed, that the maximum temperature rise for a given core radius of 10 nm ranges between 2.1 n°K and 8.8 n°K depending on the MFP.

Similar results were received by Keblinski et al. [38] and Rabin [31] for a constant heat flux and an MNP’s having approximately the same physical and magnetic properties. The very low absolute change in temperature caused by a single MNP can be explained by its low magnetic susceptibility 𝜒0, and by the effective relaxation time that changes drastically with the MNP’s volume [15]. Therefore, a single MNP can release only a small amount of heat causing a very small change in the temperature surrounding it.

However, for larger magnetic concentration occupying a single cell such as 1 ng of Fe3O4 per human cell, that is, equivalent to 5107 MNPs per cell (for a particle radius 10 nm and cell radius 5 μm), Linh et al. [66] and Balivada et al. [67] showed that a local temperature elevation of several degrees can be reached making MH treatments effective. In addition, these quantities were also proposed by Vera and Bayazitoglu [59], Chan et al. [61], Huang [64], and Melancon et al. [65] who proved their efficiency in inducing MH. Consequently, one can produce a significant global temperature increment inside a cell even if the local temperature increment of each particle is negligible as long as we heat many particles in the same volume of interest.

For the multiparticle case, Rabin [31], and Keblinski et al. [38] calculated the temperature rise inside a spherical region with radius 𝑅 (m) consisting of many randomly dispersed heat sources using Δ𝑇global(𝑡)=(𝑅2Δ𝑇nano(𝑡)/𝑟𝑝2)(4𝜋/3)𝑟𝑝3𝜌𝑁, where 𝜌𝑁 (m−3) is the number of MNPs per unit volume, 𝑘 (Wm−1°C−1) is the thermal conductivity of the medium, 𝑟𝑝 (m) is the radius of MNPs, and Δ𝑇nano(𝑡) is the temperature gradient caused by a single MNP.

For 𝜌𝑁=51021 (m−3) and an average tumor cell radius of 𝑟cell=7μm [52], the number of MNPs inside a single cell can be calculated to equal 8106 that fits the concentrations found by Linh et al. [66] and Balivada et al. [67]. From 𝜌𝑁, we calculated the distances between two neighboring particles that is approximately 58 nm. This means that the volume fraction of the MNPs inside the cell is about 0.02.

By choosing a solid volume fraction of 𝜙=0.032, the calculated distance between two neighboring particles is about 50 nm fitting a concentration of 𝜌𝑁=81021 m−3, that is, in the toxicity safety range, for a tumor cell having an average radius of 7 μm [52, 66].

Due to the large distances between the particles, we assumed that the interparticle interactions are negligible, so the relaxation time and magnetic susceptibility can be calculated using the same expression as (5) [68].

The total temperature increment for the three cases analyzed in this paper can be found by substituting the received values for the single-MNP case, (9), (12), and (15) into Δ𝑇global(𝑡) when average tumor radius of 𝑅=4 mm was assumed in consistence with magnitudes of cancer tumors [31, 38, 67].

For the cosine MFP an average value of Δ𝑇global_cos(𝑡)=2.9K over one cycle is received near the MNP’s surface. This means that the MNP’s concentration is not sufficient to give increment to a dramatic temperature gradient under the parameters summarized in Tables 1 and 2.

In order to receive a 6° increment, that is needed for MH, in the temperature near the MNP’s surface, a larger amount than the proposed of particles is required.

For the PMP, an average value of Δ𝑇global_pulsed(𝑡)=7.2K over one cycle is received for the same parameters summarized in Tables 1 and 2 that is sufficient to induce MH.

For the discontinuous pulse-shaped MF, a maximum peak of Δ𝑇global_pulsed_cos(𝑡)=1.23K over one cycle is received, meaning that the MNP’s concentration in this case as in Case 1 is not sufficient to ensure that MH can occur.

The comparison between the three temperature gradients received for each case, shows that the preferable MFP for MH is the PMP one, compared to Case 1 and Case 3. For Case 2, the temperature gradient at the surface of the MNP is sufficient to cause damage to biologic cells [58, 69, 70]. Therefore, using a periodic pulse MFP can reduce the necessary amount of MNPs by a factor or even more, allowing a wider range of markers to be used for hyperthermia treatments, and simplifying the biological processes to conjugate them to a cell.

In addition, we also explored the influence that the MNP’s radius has on the maximal temperature gradient an on its rate rise. As seen from Figures 4, 6, and 8, the NP size has a great influence on determining the amount of heat released from the MFP’s surface effecting both the temperature gradient as well as the temperature rise rate, as previous works showed [50, 51, 70].

For the first Case 1 studied, the optimal core radius was found as 9.3 nm where the maximal temperature reaches 4.7 n°K and the temperature change rate equals 0.011°Ks−1 (Figure 4). This optimal radius was also received by Kappiyoor et al. [47] for almost the same MF properties and magnetic material properties. However, because the equation solved by Kappiyoor et al. [47] is different than (1), the maximal value is slightly lower that the values received by Rosensweig [4] and Kappiyoor et al. [47]. Moreover, the maximal value is also affected by the parameters chosen to describe the magnetic properties of the MNP, as demonstrated by Kappiyoor et al. [47]. Our magnetic parameters are slightly different than the ones used by Rosensweig [4] and Kappiyoor et al. [47], which may account for the differences in the maximal values in this study as Kappiyoor et al. [47] showed.

For Case 2 studied, the optimal core radius was found as 8.3 nm where the maximal temperature gradient reaches 32 n°K, and the temperature change rate equals 1.1°Ks−1 for a summation of 25 indexes (Figure 6). As can be seen by comparison, there is a benefit in using a PMP rather than a cosine MF, due to the higher temperature gradient received in the MNP’s surrounding and the sufficient average temperature gradient received per cycle that is about 2.5 times higher in Case 2 than in Case 1.

Although for a total summation of 25 indexes, the temperature change rate is approximately 1°Ks−1, (suggested to be less safe [47]), one can reduce the received value by limiting the number of the summation indexes composing the MF to a lower number such as 𝑁=10 instead of 𝑁=25, making the treatment safer but also maintaining higher temperature values that in Case 1 (Figure 14). Furthermore, when looking at the results of multiplying each coefficient’s amplitude with its matched harmonic, the limitation for the treatment to be biologically noninvasive remains valid as long as 𝐴e𝑓05109 A/m·s as mathematically justified in (A.29) and (A.30) limiting the total summation index to a value lower than 𝑁=25.

For the Case 3 studied, the optimal core radius was found as 9 nm where the maximal temperature reaches 0.64 μ°K and the temperature change rate equals 27.3°Ks−1 (Figure 8). Although the values are higher than the ones received for the first case, the average temperature elevation was found to be lower after normalizing it to the time period, making this type of MFP less preferable.

As we can see for all the three cases analyzed in this paper, the optimal radius depends very much on the magnetic material properties [47] and on the profile of the magnetic field as we have proven in Section 2. Therefore, for each case studied and for each magnetic material the equations, developed for Cases 13 must be solved separately in order to optimize the MH treatment.

Another interesting finding driven from the mathematical equations, is the confinement of the temperature to an area having an average radius of 12 nm from the MNP’s surface for all three cases. This means that most of the heat dissipation occurs in the vicinity of the heat sources confining the temperature increment in the proximity of tumor cells alone unaffecting the healthy cells.

The importance of this paper lies in the fact that, until now there was no explicit mathematical formulation that solves the DHFE equation for other types of periodic MFPs used as excitation sources for MH treatments. As we found out, changing the profile of the MF radiation can induce higher temperature gradients in tumor cells, for the same physical and thermal parameters enabling reduction of the MNPs concentration per cell. This is of great importance because, a typical cell has a maximal quantity of MNPs that it can uptake, and because high concentration of MNPs with different types of coatings can cause a toxic reaction to the central nervous system [62]. Therefore, lowering the magnetic concentration per cell, but still receiving the same temperature gradients may be of great use.

With the outcome of this paper, we are moving forward to in vitro studies in order to verify the theoretical results received in this paper experimentally.

5. Conclusions

This study investigates the effects of different heat-flux profiles on a single MNP immobilized inside a phantom having the same thermal properties as a muscle tissue. The exact solution of DHFE was solved for different boundaries conditions using FTs. According to the analytic solutions, the PMP profile was found to be the more effective in rising the temperature of the medium surrounding the MNP than the cosine profile, making it a better candidate for hyperthermia treatments rather than the conventional cosine MP.

Moreover, in order to reach a significant temperature gradient for all cases studied (a) a cosine profile, (b) a PMP profile, and (c) a discontinuous cosine profile, there is a need for a larger number of MNPs to be immobilized inside the cell medium as Rabin [31] and Keblinski et al. [38] previously suggested. Using their techniques, a significant temperature rise was achieved for the periodic pulse-shaped MF in comparison to the other two cases studies.

In order to understand the influences that a denser cluster has on the temperature gradient, other studies should be done investigating the interparticle interactions affecting the temperature increment and its derivative.

Appendices

A. Methods

In this appendix, we are deducing the equations for the temperature profiles introduced in Section 2, step by step. For simplicity, new variables are used to solve (1), where: 𝑅=1𝛼𝑚𝑟,𝛼𝑚=𝑘𝑚𝜌𝑚𝑐𝑚,𝜃(𝑅,𝑡)=𝑘𝑚𝑇𝑚(𝑅,𝑡)𝑇𝑏𝑅,𝑅0=1𝛼𝑚𝑎.(A.1) Therefore, by substituting the new variables from (A.1) into the left part of (1) we receive the following: 𝑘𝑚2𝑇𝑚𝑘(𝑟,𝑡)=𝑚𝑟𝜕2𝑟𝑇𝑚(𝑟,𝑡)𝜕2𝑟||||𝑇𝑚𝑚𝑅(𝑟,𝑡)𝜃(𝑅,𝑡)/𝑘𝑟𝑅𝛼𝑚=1𝛼𝑚𝜕2𝜃(𝑅,𝑡)𝑅𝜕2𝑅.(A.2) And by substituting the new variables from (A.1) into the right part of (1) we receive that: 𝜌𝑚𝑐𝑚𝜕𝑇𝑚(𝑟,𝑡)=𝜌𝜕𝑡𝑚𝑐𝑚𝑘𝑚𝜕𝜃(𝑅,𝑡)|||𝑅𝜕𝑡𝛼𝑚𝑘𝑚/(𝜌𝑚𝑐𝑚)=1𝛼𝑚𝜕𝜃(𝑅,𝑡).𝑅𝜕𝑡(A.3) So (1) can be rewritten as follows: 𝜕2𝜃(𝑅,𝑡)𝜕2𝑅=𝜕𝜃(𝑅,𝑡).𝜕𝑡(A.4) The same procedure can be done to the BC, substituting the new variables from (A.1) into the left part of (2) to receive the following: 𝑘𝑚𝑇𝑚(𝑟,𝑡)𝑟||||𝑟=𝑎=𝑘𝑚𝜕𝑇𝑚(𝑟,𝑡)||||𝜕𝑟𝑇𝑚𝑚𝑅(𝑟,𝑡)𝜃(𝑅,𝑡)/𝑘𝑟𝑅𝛼𝑚1=𝛼𝑚𝜕𝜕𝑅𝜃(𝑅,𝑡)𝑅1=𝛼𝑚𝑅𝜃(𝑅,𝑡)𝑅|||||𝑅=𝑅0,(A.5) And (2) can be rewritten as follows: 𝜃(𝑅,𝑡)𝑅||||𝑅=𝑅0=𝑞𝑠(𝑡)𝛼𝑚.(A.6) By taking the FT of (A.4) (defined as in (4)) one receives the transformation in the frequency domain, so ̃𝜕0=𝑖𝜔𝜃(𝑅,𝜔)2̃𝜃(𝑅,𝜔)𝜕2𝑅.(A.7) The general solution of (A.7) can be found as follows: ̃𝜃(𝑅,𝜔)=𝑐2(𝜔)𝑒𝑖𝜔𝑅.(A.8) Substituting (A.8) into the LT of (A.6), the BC can be written as follows: 𝑐2𝑎𝑖𝜔+𝛼𝑚𝑎2=̃𝑞𝑠(𝜔)𝑒𝑖𝜔𝑅0.(A.9) So ̃𝑎𝜃(𝑅,𝜔)=2𝛼𝑚𝑎/𝛼𝑚𝑖𝜔+1̃𝑞𝑠(𝜔)𝑒𝑖𝜔(𝑅𝑅0)=𝑎𝑅0𝑅0𝑖𝜔+1̃𝑞𝑠(𝜔)𝑒𝑖𝜔(𝑅𝑅0).(A.10) Using technical computing software (Maple or/and Wolfram Mathematica) the inverse FT of ̃𝜃(𝑅,𝜔)/̃𝑞𝑠(𝜔)=𝜙(𝑅,𝜔) for 𝑡>0, can be found by substituting 𝑖𝜔𝑠 in (A.10) and taking the inverse Laplace transform of the received equation so that 𝑒𝜙(𝑅,𝑡)=𝑎(𝑅𝑅0)2/4𝑡𝜋𝑡erfc𝑅𝑅0/2𝑡+𝑡/𝑅0𝑒(𝑅𝑅0)/𝑅0+𝑡/𝑅02𝑅0.(A.11) This function converges to 0 for 𝑡 or/and for 𝑅𝑅0.

So the changes in the temperature can be found using (A.1) and (A.10) as follows. Δ𝑇𝑚(𝑟,𝑡)=𝜃(𝑅,𝑡)𝑘𝑚𝑟𝛼𝑚=𝜙(𝑅,𝑡)𝑞𝑠(𝑡)𝑘𝑚𝑟𝛼𝑚.(A.12) Equation (A.12) slightly differs than the one received by Keblinski et al. [38] due to the BC that define the heat flux coming from the surface of the MNP defining the heat created by the magnetic losses inside it, whereas Keblinski et al. [38] suggested that the heat sources are inside the medium of interest and that the heat-power density is constant in time. In order to analytically calculate (3) or (A.12), the general expression of 𝑞𝑠(𝑡) (Wm−2) must be found for each case.

Case 2 (a cosine MFP). For Case 1, the magnetization, 𝑀(𝑡), can be found in the time domain after substituting (5) and the MF in (4) and taking the inverse FT of it, that results in 𝑀(𝑡)=𝜒(𝑡)=𝐻(𝑡)𝐴𝜒0𝜏𝜔cos0𝑡𝜏+𝜔0𝜔sin0𝑡1(1/𝜏)2+𝜔02.(A.13) Substituting (A.13) into the magnetic induction [5] results in 𝐵(𝑡)=𝜇0𝐻(𝑡)+𝜇0𝑀(𝑡).(A.14) Further substituting the received magnetic induction described in (A.14) into (7), one can calculate the conversion of the magnetic energy into heat losses, resulting in 𝐇(𝐭)𝜕𝐁(𝐭)=𝜕𝑡𝑑𝜔𝑑𝜔𝐻𝑟,𝜔𝑖𝜔𝜇0𝜇(𝜔)𝐻(𝑟,𝜔)𝑒𝑖(𝜔𝜔)𝑡=𝜇0𝐴2𝜔cos0𝑡𝜒𝑑𝜔𝑖𝜔1+0×𝛿1+𝑖𝜔𝜏𝜔𝜔0+𝛿𝜔+𝜔02𝑒𝑖𝜔𝑡=𝜇0𝐴2𝜔cos0𝑡𝜔0×𝜔0𝜒0𝜏1+𝜔02𝜏2𝜔cos0𝑡𝜔sin0𝑡𝜒1+01+𝜔02𝜏2=𝑃Loss(𝑡)+𝜕𝑈.𝜕𝑡(A.15) Or 𝑃Loss(𝑡)=𝜇0𝐴2𝜔cos0𝑡𝜔0𝜔0𝜒0𝜏1+𝜔02𝜏2𝜔cos0𝑡.(A.16) Because 𝑃Loss(𝑡) is only a function of time between 0<𝑟<𝑎 (isotropic and homogeneous material), then the outward heat flux at 𝑟=𝑎 can be calculated as follows: 𝑞𝑠(𝑟=𝑎,𝑡)4𝜋𝑎2=4𝜋𝑎33𝑃Loss(𝑡).(A.17) Or 𝑞𝑠(𝑟=𝑎,𝑡)=𝑎𝜇0𝐴2𝜔06𝜔0𝜒0𝜏𝜔1+0𝜏2cos2𝜔0𝑡.+1(A.18) Taking the FT of (A.18) and substituting it in (A.10) one can calculate the FT of 𝜃(𝑅,𝑡) to receive the following: ̃𝜃(𝑅,𝜔)=𝑎𝜇0𝐴2𝜔06×𝜔0𝜒0𝜏𝜔1+0𝜏2𝛿𝜔2𝜔0+𝛿𝜔+2𝜔02+𝛿(𝜔)𝑎𝑅0𝑅0𝑖𝜔+1exp.𝑖𝜔𝑅(A.19)

Case 3 (a PMP profile). The PMP, (11), can be decomposed using the theory of Fourier’s series into its harmonics to receive [71, 72] the following: Δ𝐻(𝑡)=2𝐴𝑇𝑠+𝑛=14𝐴𝜋𝑛sin𝑛𝜋Δ𝑇𝑠cos𝑛𝜔0𝑡.(A.20) By substituting (A.20) into (A.14) and then using them in (7) we can calculate the total heat dissipation for this case as follows: 𝐇(𝐭)𝜕𝐁(𝐭)=𝜕𝑡𝑑𝜔𝑑𝜔𝐻𝑟,𝜔𝑖𝜔𝜇0𝜇(𝜔)𝐻(𝑟,𝜔)𝑒𝑖(𝜔𝜔)𝑡=𝜇0Δ2𝐴𝑇𝑠+4𝐴𝜋𝑚sin𝑚𝜋Δ𝑇𝑠cos𝑚𝜔0𝑡4𝐴𝜋𝑛sin𝑛𝜋Δ𝑇𝑠𝜒𝑑𝜔𝑖𝜔1+0×𝛿1+𝑖𝜔𝜏𝜔𝑛𝜔0+𝛿𝜔+𝑛𝜔02𝑒𝑖𝜔𝑡=𝜇0Δ2𝐴𝑇𝑠+4𝐴𝜋𝑚sin𝑚𝜋Δ𝑇𝑠cos𝑚𝜔0𝑡4𝐴𝜋sin𝑛𝜋Δ𝑇𝑠𝜔0×𝑛𝜔0𝜒0𝜏1+𝑛𝜔02𝜏2cos𝑛𝜔0𝑡sin𝑛𝜔0𝑡𝜒1+01+𝑛𝜔02𝜏2=𝑃Loss(𝑡)+𝜕𝑈.𝜕𝑡(A.21) Therefore, we can find that the heat losses equal to 𝑃Loss(𝑡)=𝜇0Δ2A𝑇𝑠+4𝐴𝜋𝑚sin𝑚𝜋Δ𝑇𝑠cos𝑚𝜔0𝑡4𝐴𝜋sin𝑛𝜋Δ𝑇𝑠𝜔0𝑛𝜔0𝜒0𝜏1+𝑛𝜔02𝜏2cos𝑛𝜔0𝑡.(A.22) And for Δ<𝑡<𝑇𝑠: 𝐇(𝐭)𝜕𝐁(𝐭)𝜕𝑡=0.(A.23) Using (A.17) and (A.22) we can calculate the heat flux at the surface of the MNP. 𝑞𝑠(𝑟=𝑎,𝑡)=𝑃Loss𝑎(𝑡)3=𝑎3𝜇0Δ2𝐴𝑇𝑠+4𝐴𝜋𝑚sin𝑚𝜋Δ𝑇𝑠cos𝑚𝜔0𝑡4𝐴𝜋sin𝑛𝜋Δ𝑇𝑠𝜔0𝑛𝜔0𝜒0𝜏1+𝑛𝜔02𝜏2cos𝑛𝜔0𝑡.(A.24) By taking the FT of the resulted heat flux and substituting it in (A.10) one can receive ̃=𝑎𝜃(𝑅,𝜔)38𝜔0𝜇0𝐴2Δ𝜋𝑇𝑠sin𝑛𝜋Δ𝑇𝑠𝑛𝜔0𝜒0𝜏1+𝑛𝜔02𝜏2×𝛿𝜔𝑛𝜔0+𝛿𝜔+𝑛𝜔02𝑎𝑅0𝑅0𝑖𝜔+1exp+𝑎𝑖𝜔𝑅38𝜇0𝐴2𝜔0𝜋2sin𝑚𝜋Δ/𝑇𝑠𝑚sin𝑛𝜋Δ𝑇𝑠×𝑛𝜔0𝜒0𝜏1+𝑛𝜔02𝜏2𝛿𝜔(𝑛+𝑚)𝜔0+𝛿𝜔+(𝑛+𝑚)𝜔02+𝛿𝜔(𝑚𝑛)𝜔0+𝛿𝜔+(𝑚𝑛)𝜔02×𝑎𝑅0𝑅0𝑖𝜔+1exp.𝑖𝜔𝑅(A.25)

When looking at (A.25), the multiplication of each coefficient’s amplitude with its matched harmonic must meet the biologically noninvasive limitation 𝐴𝑚𝑓𝑚5109A/m·s. The mathematical justification is deduced next.

Looking at the eddy currents that evolve in the body [73] 𝐸(𝜔)=𝑖𝜔𝑟2𝐵𝑧,𝐽(𝜔)=𝑖𝜔𝑟𝜎2𝐵𝑧𝑟𝐸(𝑡)=2𝜕𝐵𝑧(𝑡)𝜕𝑡=𝜇0𝑟2𝜕𝐻(𝑡),𝜕𝑡𝐽(𝑡)=𝑟𝜎2𝜕𝐵𝑧(𝑡)𝜇𝜕𝑡=0𝑟𝜎2𝜕𝐻(𝑡).𝜕𝑡(A.26) They can be written using (A.20) as follows: 𝐸(𝑡)=𝜇0𝑟2𝜕𝐻(𝑡)𝜕𝑡=𝜇0𝑟2𝜔04𝐴𝜋sin𝑚𝜋Δ𝑇𝑠sin𝑚𝜔0𝑡,𝜇𝐽(𝑡)=0𝑟𝜎2𝜕𝐻(𝑡)=𝜇𝜕𝑡0𝑟𝜎2𝜔04𝐴𝜋sin𝑛𝜋Δ𝑇𝑠sin𝑛𝜔0𝑡.(A.27) So the eddy losses inside the body can be found using Poynting theory [5] as follows: 𝑃average=1𝑇𝑠1𝑃(𝑡)𝑑𝑡=𝑇𝑠=𝜎𝐸(𝑡)𝐽(𝑡)𝑑𝑡𝑇𝑠2𝑟𝜔0𝜇0𝐴𝜋2sin𝑚𝜋Δ𝑇𝑠sin𝑚𝜔0𝑡×sin𝑛𝜋Δ𝑇𝑠sin𝑛𝜔0𝑡=𝜎𝑑𝑡𝑇𝑠𝜋𝑟𝑓0𝜇024𝐴𝜋2sin2𝑚𝜋Δ𝑇𝑠×sin2𝑚𝜔0𝑡𝑑𝑡=𝜎𝜋𝑟𝑓0𝜇024𝐴𝜋212sin2𝑚𝜋Δ𝑇𝑠=𝐴e2𝜎𝜋𝑟𝑓0𝜇02.(A.28) The last expression is the same as the one received by Atkinson et al. [16]. Therefore the limitation on the MFS and the frequency can be summarized as follows [11, 16, 24]: 𝐴e𝑓0=𝑓04𝐴𝜋2sin2𝑚𝜋Δ𝑇𝑠5109A/ms.(A.29) For 𝑁=25 and a duty cycle of 𝑑=Δ/𝑇𝑠=0.2, the treatment is safe as long as 𝐴e𝑓0=𝑓04𝐴𝜋2sin2𝑚𝜋Δ𝑇𝑠=𝐴𝑓03.15109A/ms.(A.30) Consequently, as long as (A.30) is valid the treatment is safe. Choosing other maximal summation index values such as 𝑁=20 will result in a new constraint over the frequency and the MFS that must fulfill 𝐴e𝑓0=𝑓0(4𝐴/𝜋2)sin2(𝑚𝜋Δ/𝑇𝑠)𝐴𝑓02.85109 A/m·s and so on.

Moreover, for frequencies lower than 10 MHz there is essentially no attenuation of the MFS within cylinders of muscle-equivalent material, therefore the maximal harmonic frequency should not exceed 10 MHz [16].

Case 4 (a discontinuous cosine MFP). As for the previous case, we decompose the MF using the theory of Fourier’s series into its harmonics for 0𝑡Δ to receive [71, 72] =𝐻(𝑡)𝑛=12𝐴𝑇𝑠(𝜔sinΔ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+(𝜔sinΔ/2)0𝑛𝜔1𝜔0𝑛𝜔1×cos𝑛𝜔1𝑡.(A.31)

For Δ𝑡𝑇𝑠, the magnetic power losses are zero, because the MF dose not exists.

By substituting (A.31) into (A.14) and then using them in (7) we can calculate the total heat dissipation for this case as follows:𝐇(𝐭)𝜕𝐁(𝐭)=𝜕𝑡𝑑𝜔𝑑𝜔𝐻𝑟,𝜔𝑖𝜔𝜇0𝜇(𝜔)𝐻(𝑟,𝜔)𝑒𝑖(𝜔𝜔)𝑡=𝜇02𝐴𝑇𝑠2(𝜔sinΔ/2)0+𝑚𝜔1𝜔0+𝑚𝜔1+𝜔sin(Δ/2)0𝑚𝜔1𝜔0𝑚𝜔1×cos𝑚𝜔0𝑡𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+𝜔sin(Δ/2)0𝑛𝜔1𝜔0𝑛𝜔1×𝜒𝑑𝜔𝑖𝜔1+0×𝛿1+𝑖𝜔𝜏𝜔𝑛𝜔1+𝛿𝜔+𝑛𝜔12𝑒𝑖𝜔𝑡=𝜇02𝐴𝑇𝑠2×𝜔sin(Δ/2)0+𝑚𝜔1𝜔0+𝑚𝜔1+𝜔sin(Δ/2)0𝑚𝜔1𝜔0𝑚𝜔1×cos𝑚𝜔1𝑡𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+𝜔sin(Δ/2)0𝑛𝜔1𝜔0n𝜔1×𝑛𝜔12𝜒0𝜏1+𝑛𝜔12𝜏2cos𝑛𝜔1𝑡sin𝑛𝜔1𝑡𝜒1+01+𝑛𝜔12𝜏2=𝑃Loss(𝑡)+𝜕𝑈.𝜕𝑡(A.32) Therefore, we can find that the heat losses equal to 𝑃Loss(𝑡)=𝜇02𝐴𝑇𝑠2×𝜔sin(Δ/2)0+𝑚𝜔1𝜔0+𝑚𝜔1+𝜔sin(Δ/2)0𝑚𝜔1𝜔0𝑚𝜔1×cos𝑚𝜔1𝑡𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+𝜔sin(Δ/2)0𝑛𝜔1𝜔0𝑛𝜔1×𝑛𝜔12𝜒0𝜏1+𝑛𝜔12𝜏2cos𝑛𝜔1𝑡.(A.33) Using (A.17) and (A.33) we can calculate the heat flux at the surface of the MNP. 𝑞𝑠(𝑟=𝑎,𝑡)=𝑃Loss𝑎(𝑡)3=𝑎3𝜇02𝐴𝑇𝑠2𝜔sin(Δ/2)0+𝑚𝜔1𝜔0+𝑚𝜔1+𝜔sin(Δ/2)0𝑚𝜔1𝜔0𝑚𝜔1cos𝑚𝜔1𝑡𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+𝜔sin(Δ/2)0𝑛𝜔1𝜔0𝑛𝜔1×𝑛𝜔12𝜒0𝜏1+𝑛𝜔12𝜏2cos𝑛𝜔1𝑡.(A.34) By taking the FT of the resulted heat flux and substituting it in (A.10) one can receive ̃=𝜃(𝑅,𝜔)2𝑎3𝜇0𝐴𝑇𝑠2𝑎𝑅0𝑅0𝑖𝜔+1exp×𝜔𝑖𝜔𝑅sin(Δ/2)0+𝑚𝜔1𝜔0+𝑚𝜔1+𝜔sin(Δ/2)0𝑚𝜔1𝜔0𝑚𝜔1×𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+𝜔sin(Δ/2)0𝑛𝜔1𝜔0𝑛𝜔1𝑛𝜔12𝜒0𝜏1+𝑛𝜔12𝜏2×𝛿𝜔(𝑛+𝑚)𝜔1+𝛿𝜔+(𝑛+𝑚)𝜔12+𝛿𝜔(𝑚𝑛)𝜔1+𝛿𝜔+(𝑚𝑛)𝜔12.(A.35) When looking at (A.35) the multiplication of each coefficient’s amplitude with its matched harmonic must meet the biologically noninvasive limitation 𝐴𝑚𝑓𝑚5109A/m·s. The mathematical justification is deduced next.

For 𝑓0>𝑓1 and 𝑇𝑠=1/𝑓1, we find that (A.26) becomes 𝐸(𝑡)=𝜇0𝑟2𝜕𝐻(𝑡)𝜕𝑡=𝜇0𝑟2𝜔1𝑛2𝐴𝑇𝑠𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+(𝜔sinΔ/2)0𝑛𝜔1𝜔0𝑛𝜔1sin𝑛𝜔1𝑡,𝜇𝐽(𝑡)=0𝑟𝜎2𝜕𝐻(𝑡)=𝜇𝜕𝑡0𝑟𝜎2𝜔1×𝑚2𝐴𝑇𝑠𝜔sin(Δ/2)0+𝑚𝜔1𝜔0+𝑚𝜔1+𝜔sin(Δ/2)0𝑚𝜔1𝜔0𝑚𝜔1sin𝑚𝜔1𝑡.(A.36) Consequently, (A.28) becomes 𝑃avr=1𝑇𝑠1𝑃(𝑡)𝑑𝑡=𝑇𝑠=𝜎𝐸(𝑡)𝐽(𝑡)𝑑𝑡𝑇𝑠2𝑟𝜔1𝜇0𝐴𝑇𝑠2𝑛𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝑛𝜔1+𝜔sin(Δ/2)0𝑛𝜔1𝜔0𝑛𝜔1sin𝑛𝜔1𝑡×𝑚𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+𝜔sin(Δ/2)0𝑛𝜔1𝜔0𝑛𝜔1sin𝑛𝜔1𝑡=𝜎𝑑𝑡𝑇𝑠2𝑟𝜔1𝜇0𝐴𝑇𝑠2×𝑛2𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+𝜔sin(Δ/2)0𝑛𝜔1𝜔0𝑛𝜔12×sin2𝑛𝜔1𝑡𝑑𝑡=𝜎𝜋𝑟𝑓1𝜇024𝐴𝑇𝑠2×12𝑛2𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+𝜔sin(Δ/2)0𝑛𝜔1𝜔0𝑛𝜔12=𝐴e2𝜎𝜋𝑟𝑓1𝜇02.(A.37) The last expression is the same as the one received by Atkinson et al. [16]. Therefore, the limitation on the MFS and the frequency can be summarized as follows [11, 16, 24]: 𝐴e𝑓1=𝑓14𝐴𝑇𝑠2×𝑛2𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+𝜔sin(Δ/2)0𝑛𝜔1𝜔0𝑛𝜔125109A/ms.(A.38) For 𝑁=25, a duty cycle of 𝑑=Δ/𝑇𝑠=0.2 and 𝜔0=6𝜔1, the treatment is safe as long as 𝐴e𝑓1=𝑓14𝐴𝑇𝑠2×𝑛2𝜔sin(Δ/2)0+𝑛𝜔1𝜔0+𝑛𝜔1+𝜔sin(Δ/2)0𝑛𝜔1𝜔0𝑛𝜔12=𝐴𝑓14.6<𝐴𝑓05109A/ms.(A.39)

Consequently, as long as (A.39), the treatment will be safe. Moreover, for frequencies lower than 10 MHz, there is essentially no attenuation of the MFS within cylinders of muscle-equivalent material, therefore the maximal harmonic frequency should not exceed 10 MHz [16].

B. COMSOL: Results

In order to validate the analytic solutions and the MATLAB simulations, a numerical simulation was performed using COMSOL, for the same thermal and magnetic properties given in Tables 1 and 2. The simulation results can be seen for each case studied in Methods and Results parts in this Appendix.

For Case 1, the mathematical expression of the temperature increment, (9), was plotted as a function of time and space, where the results are given in Figure 10 for 𝑇𝑠=2.5μs.

135708.fig.0010
Figure 10: The temperature profile for a cosine MFP plotted as a function of time and as a function of the observation point located at a distance, 𝑟, from the surface of the MNP; 𝑟 ranging from 0 nm to 10 nm for a core radius of 10 nm.

The maximal temperature elevation in Figure 10 reached a value of 2.25 n°K on the surface of the MNP which is 0.15 n°K higher than the one received for the analytic simulation, Figure 3.

At 2 nm apart from the surface of the MNP surface, the temperature elevation reached a value of 2.05 n°K that is 0.2 n°K higher than the one receive in Figure 3. Again, there is a small difference between both simulations results. As the observation point gets further from the surface of the MNP, the temperature differences get bigger; reaching a value of 0.4 n°K at an observation point located 10 nm apart from the surface.

This may be caused by the triangles constructing the COMSOL’s numeric mesh, which are used to solve numerically the heat problem, that get larger and bigger, as the observation point gets further from the MNP surface contributing to the error.

Comparing between Figures 3 and 10 we conclude that the numerical simulation fits the analytic solution.

For Case 2, as in Case 1, in order to validate the analytic solution a numerical simulation was also performed using COMSOL for the same thermal and magnetic properties (Tables 1 and 2). The simulation result can be seen in Figure 11.

135708.fig.0011
Figure 11: The temperature profile for a PMP-shaped MFP plotted as a function of time and as a function of the observation point located at a distance, 𝑟, from the surface of the MNP; 𝑟 ranging from 0 nm to 10 nm for a core radius of 10 nm for 𝑁=25.

The maximal temperature elevation in Figure 11 reaches a value of 8.5 n°K on the surface of the MNP, which is 0.4 n°K higher than the one receive in Figure 5.

At 2 nm apart from the surface of the MNP surface, the temperature elevation reached a value of 7.5 n°K, that is 0.2 n°K higher than the one receive in Figure 5. Again, it seems that there exists a small difference between the simulations results. As the observation point gets further from the surface of the MNP, the differences gets bigger reaching a value of 0.8 n°K at an observation point located 10 nm a part from the surface.

This may be caused by the bigger triangles in the mesh that are formed in the COMSOL software as the observation point gets further from the MNP surface contributing to the error.

As can be seen from Figure 11, there are 5 peaks during the time that the MF is tuned on that fit the number of peaks in Figure 5, these peaks evolve due to the final number of harmonics that form the PMP MF, as given by (11). However, there is a slightly difference in the temperature profiles between Figures 11 and 5; in Figure 11 the first peak is lower than the others in comparison to Figure 5 where the first peak is about the same high as the last peak.

Again, there are some small changes between both software simulations as expected; however the results for both simulations conclude that there is a benefit in using the PMPs instead of the cosine MFP due to the higher temperature rise values received for the same magnetic parameters.

For Case 3, we used again the numerical simulation COMSOL in order to validate the analytic solution for the same thermal and magnetic properties. The simulation result can be seen in Figure 12.

135708.fig.0012
Figure 12: The temperature profile for a discontinuous cosine MFP plotted as a function of time and as a function of the observation point located at a distance, 𝑟, from the surface of the MNP; 𝑟 ranging from 0 nm to 10 nm, for a core radius of 10 nm for 𝑁=25.

The maximal temperature elevation in Figure 12 reached a value of 2.3 n°K on the surface of the MNP which is the same as the one receive in Figure 7.

At 2 nm apart from the surface of the MNP surface the temperature elevation reached a value of 2 n°K, that is, 0.2 n°K higher than the one received in Figure 7. Again, there is a small difference between the simulations results. As the observation point get further from the surface of the MNP, the differences gets bigger reaching a value of 0.3 n°K at an observation point located 10 nm a part from the surface.

As explain before, this may be caused by the bigger triangles in the mesh that are formed in the COMSOL software as the observation point gets further from the MNP surface contributing to the error. Although, there are some small changes between both simulations as expected, the maximal temperature rise is almost the same as the cosine MFP.

C. The Effects the Maximal Number of Indexes Has on Cases 2 and 3: Results

In Appendix C, we examined the influences that the maximal numbers of indexes composing the MF signal have on the temperature rise and on the temperature rate rise for Case 2 and Case 3.

The maximal index numbers for summation were chosen as 𝑁=100, 𝑁=25, 𝑁=15, 𝑁=10, and 𝑁=1. Above 𝑁=25 the MF is practically absorbed in the tissue [14], but this fact was not taken in consideration in the simulations results.

Case 3. The temperature rise for Case 2, as a function of the maximal summation indexes can be seen in Figure 13.

135708.fig.0013
Figure 13: The absolute maximal temperature rise was plotted as a function of the number of harmonics summed, 𝑁, and as a function of the core radius for a periodic pulse-shaped MFP having a pulsed width of 0.2𝑇𝑠; the maximal summation value 𝑁 ranges from 𝑁=1 to 𝑁=100.
135708.fig.0014
Figure 14: The absolute maximal temperature rise rate was plotted as a function of the number of harmonics summed, 𝑁, and as a function of the core radius for a periodic pulse-shaped MFP having a pulsed width of 0.2 𝑇𝑠 plotted as a function of the core radius; 𝑎: ranging from 5 nm to 15 nm, the observation points are on the surface of the MNP.

From Figure 13, we concluded that the maximal temperature rise depends on the number of harmonics composing the MF signal. For 𝑁=100, the maximal temperature rise reaches a value of 50 n°K for a core radius of 7.7 nm, that is, 1.6 times higher than the maximal value received for 𝑁=25. The summation of 100 indexes can be seen as the ideal PMPs shaped MFP.

For 𝑁=15, we receive a temperature rate of 28 n°K for a core radius of 8.8 nm and for 𝑁=10 we received a value of 26 n°K for a core radius of 9 nm. Furthermore, we can see that the number of indexes composing the MF changes the optimal radius as it gets smaller as the index number gets bigger.

Now, we examined the influences that the number of maximal summation indexes composing the MF signal has on the temperature rate rise. The chosen numbers were 𝑁=100, 𝑁=25, 𝑁=15, 𝑁=10, and 𝑁=1.

From Figure 14, we concluded that the maximal temperature rate rise depends on the number of harmonics composing the MF signal. For 𝑁=100, the maximal temperature rate reaches a value of 3.9°Ks−1 is received for a core radius 7.6 nm, and is 3.9 times higher than the value received for 𝑁=25. For 𝑁=15 we receive a temperature rate of 0.5°Ks−1 for a core radius of 8.2 nm, that is, half the value received for 𝑁=25, and for 𝑁=10, we received a value of 0.3°Ks−1 for a core radius of 8.5 nm.

Case 4. Now, we examined the influences that the maximal number of summation indexes composing the MF signal has on the temperature rise. The chosen numbers were 𝑁=100, 𝑁=25, 𝑁=15, 𝑁=10, and 𝑁=1.
From Figure 15, we concluded that the maximal temperature rise depends on the number of harmonics composing the MF signal. For 𝑁=100, the maximal temperature rise reaches a value of 5 n°K for a core radius of 9.3 nm, that is, 1.1 times higher than the maximal value received for 𝑁=25. For 𝑁=15, we receive a temperature rate of 5.5 n°K for a core radius of 9.2 nm, and for 𝑁=10, we received a value of 6.1°K for a core radius of 9.3 nm. As already mentioned, there is a limitation to the highest frequency that can be used for MH and should not exceed 10 MHz [16], in our case this limits the summation to 25 indexes that compose the MF signal. Moreover, we can see that the number of indexes composing the MF changes the optimal radius; it gets smaller as the index number gets higher. Furthermore, we can see that the number of indexes composing the MF changes the optimal radius by getting smaller as the index number gets bigger.

135708.fig.0015
Figure 15: The absolute maximal temperature rise was plotted as a function of the number of harmonics summed, 𝑁, and as a function of the maximal summation value for a periodic discontinuous cosine MFP having a pulsed width of 0.2𝑇𝑠. 𝑁 ranging from 𝑁=1 to 𝑁=100 for a core radius of 10 nm, the observation point are on the surface of the MNP.

Now, we examined the influences that the number of indexes composing the MF signal has on the temperature rate rise. The chosen numbers were 𝑁=100, 𝑁=25, 𝑁=15, 𝑁=10, and 𝑁=1.

From Figure 16, we concluded that the maximal temperature rise rate depends on the number of harmonics composing the MF signal. For 𝑁=100, the maximal temperature rate reaches a value of 0.09°Ks−1, is received for a core radius 8.4 nm, and is 4.5 times higher than the value received for 𝑁=25. For 𝑁=15, we receive a temperature rate of 0.016°Ks−1 for a core radius of 9.3 nm, that is, half the value received for 𝑁=25, and for 𝑁=10 we received a value of 0.015°Ks−1 for a core radius of 9.3 nm.

135708.fig.0016
Figure 16: The absolute maximal temperature rise rate was plotted as a function of the number of harmonics summed, 𝑁, and as a function of the core radius for a periodic discontinuous cosine MFP having a pulsed width of 0.2𝑇𝑠; 𝑎—ranging from 5 nm to 15 nm, the observation point are on the surface of the MNP.

As already mentioned there is a limitation to the highest frequency that can be used for MH and should not exceed 10 MHz [16], in our case this limits the summation to 25 indexes that compose the MF signal. Moreover, we can see that the number of indexes composing the MF changes the optimal radius and it gets smaller as the index number gets higher.

References

  1. I. M. Gescheit, M. Ben-David, and I. Gannot, “A proposed method for thermal specific bioimaging and therapy technique for diagnosis and treatment of malignant tumors by using magnetic nanoparticles,” Advances in Optical Technologies, vol. 2008, Article ID 275080, 7 pages, 2008. View at Publisher · View at Google Scholar
  2. H. G. Bagaria and D. T. Johnson, “Transient solution to the bioheat equation and optimization for magnetic fluid hyperthermia treatment,” International Journal of Hyperthermia, vol. 21, no. 1, pp. 57–75, 2005. View at Publisher · View at Google Scholar · View at Scopus
  3. M. A. Giordano, G. Gutierrez, and C. Rinaldi, “Fundamental solutions to the bioheat equation and their application to magnetic fluid hyperthermia,” International Journal of Hyperthermia, vol. 26, no. 5, pp. 475–484, 2010. View at Publisher · View at Google Scholar · View at Scopus
  4. R. E. Rosensweig, “Heating magnetic fluid with alternating magnetic field,” Journal of Magnetism and Magnetic Materials, vol. 252, no. 1–3, pp. 370–374, 2002. View at Publisher · View at Google Scholar · View at Scopus
  5. J. D. Jackson, Classical Electrodynamics, John Wily & Sons, 1998.
  6. L. D. Landau, L. P. Pitaevskii, and E. M. Lifshitz, Electrodynamics of Continuous Media, vol. 8, 2nd edition, 1984.
  7. N. Guskos, E. A. Anagnostakis, V. Likodimos et al., “Ferromagnetic resonance and ac conductivity of a polymer composite of Fe3 O4 and Fe3 C nanoparticles dispersed in a graphite matrix,” Journal of Applied Physics, vol. 97, no. 2, Article ID 024304, 6 pages, 2005. View at Publisher · View at Google Scholar · View at Scopus
  8. X. Zhang, B. Q. Li, and S. S. Pang, “A perturbational approach to magneto-thermal problems of a deformed sphere levitated in a magnetic field,” Journal of Engineering Mathematics, vol. 2-3, no. 4, pp. 337–355, 1997. View at Scopus
  9. A. Jordan, P. Wust, H. Fahlin, W. John, A. Hinz, and R. Felix, “Inductive heating of ferrimagnetic particles and magnetic fluids: physical evaluation of their potential for hyperthermia,” International Journal of Hyperthermia, vol. 9, no. 1, pp. 51–68, 1993. View at Scopus
  10. P. C. Fannin, Y. L. Raikher, A. T. Giannitsis, and S. W. Charles, “Investigation of the influence which material parameters have on the signal-to-noise ratio of nanoparticles,” Journal of Magnetism and Magnetic Materials, vol. 252, no. 1–3, pp. 114–116, 2002. View at Publisher · View at Google Scholar · View at Scopus
  11. Q. A. Pankhurst, J. Connolly, S. K. Jonesand, and J. Dobson, “Applications of magnetic nanoparticles in biomedicine,” Journal of Physics D, vol. 36, no. 13, pp. 167–181, 2003. View at Publisher · View at Google Scholar
  12. J. Weizenecker, B. Gleich, J. Rahmer, and J. Borgert, “Particle dynamics of mono-domain particles in magnetic particle imaging,” in Proceedings of the 1st International Workshop on Magnetic Particle Imaging, Magnetic Nanoparticles, pp. 3–15, World Scientific, 2010. View at Publisher · View at Google Scholar
  13. P. C. Fannin, “Magnetic spectroscopy as an aide in understanding magnetic fluids,” Journal of Magnetism and Magnetic Materials, vol. 252, no. 1–3, pp. 59–64, 2002. View at Publisher · View at Google Scholar · View at Scopus
  14. P. C. Fannin, “Characterisation of magnetic fluids,” Journal of Alloys and Compounds, vol. 369, no. 1-2, pp. 43–51, 2004. View at Publisher · View at Google Scholar · View at Scopus
  15. P. C. Fannin and S. W. Charles, “On the calculation of the Neel relaxation time in uniaxial single-domain ferromagnetic particles,” Journal of Physics D, vol. 27, no. 2, pp. 185–188, 1994. View at Publisher · View at Google Scholar · View at Scopus
  16. W. J. Atkinson, I. A. Brezovich, and D. P. Chakraborty, “Usable frequencies in hyperthermia with thermal seeds,” IEEE Transactions on Biomedical Engineering, vol. 31, no. 1, pp. 70–75, 1984. View at Scopus
  17. S. Mornet, S. Vasseur, F. Grasset, and E. Duguet, “Magnetic nanoparticle design for medical diagnosis and therapy,” Journal of Materials Chemistry, vol. 14, no. 14, pp. 2161–2175, 2004. View at Publisher · View at Google Scholar · View at Scopus
  18. C. H. Moran, S. M. Wainerdi, T. K. Cherukuri et al., “Size-dependent joule heating of gold nanoparticles using capacitively coupled radiofrequency fields,” Nano Research, vol. 2, no. 5, pp. 400–405, 2009. View at Publisher · View at Google Scholar · View at Scopus
  19. V. P. Torchilin, “Targeted pharmaceutical nanocarriers for cancer therapy and imaging,” The AAPS Journal, vol. 9, no. 2, pp. E128–E147, 2007. View at Publisher · View at Google Scholar · View at Scopus
  20. T. R. Sathe, Integrated magnetic and optical nanotechnology for early cancer detection and monitoring [Ph.D. thesis], Georgia Institute of Technology, 2007.
  21. N. Gigel, “Magnetic nanoparticles impact on tumoral cells in the treatment by magnetic fluid hyperthermia,” Digest Journal of Nanomaterials and Biostructures, vol. 3, no. 3, pp. 103–107, 2008.
  22. F. Matsuoka, M. Shinkai, H. Honda, T. Kubo, T. Sugita, and T. Kobayashi, “Hyperthermia using magnetite cationic liposomes for hamster osteosarcoma,” BioMagnetic Research and Technology, vol. 2, no. 3, pp. 1–6, 2004. View at Publisher · View at Google Scholar · View at Scopus
  23. Q. A. Pankhurst, “Nanomagnetic medical sensors and treatment methodologies,” BT Technology Journal, vol. 24, no. 3, pp. 33–38, 2006. View at Publisher · View at Google Scholar · View at Scopus
  24. E. Kita, T. Oda, T. Kayano et al., “Ferromagnetic nanoparticles for magnetic hyperthermia and thermoablation therapy,” Journal of Physics D, vol. 43, no. 47, Article ID 474011, 9 pages, 2010. View at Publisher · View at Google Scholar · View at Scopus
  25. L. Pilon and K. M. Katika, “Modified method of characteristics for simulating microscale energy transport,” Journal of Heat Transfer, vol. 126, no. 5, pp. 735–743, 2004. View at Publisher · View at Google Scholar · View at Scopus
  26. G. Chen, R. Yang, and X. Chen, “Nanoscale heat transfer and thermal-electric energy conversion,” Journal de Physique IV, vol. 125, no. 1, pp. 499–504, 2005. View at Publisher · View at Google Scholar
  27. G. Chen, “Non local and nonequilibrium heat conduction in the vicinity of nanoparticles,” Journal of Heat Transfer, vol. 118, no. 3, pp. 539–546, 1996. View at Scopus
  28. C. Kittel, Introduction to Solid-State Physics, John Wiley & Sons, New York, NY, USA, 1996.
  29. R. Röhlsberger, W. Sturhahn, T. S. Toellner et al., “Phonon damping in thin films of Fe,” Journal of Applied Physics, vol. 86, no. 1, pp. 584–592, 1999. View at Scopus
  30. K. E. Goodson and M. I. Flik, “Electron and phonon thermal conduction in epitaxial high-Tc superconducting films,” Journal of Heat Transfer, vol. 115, no. 1, pp. 17–25, 1993.
  31. Y. Rabin, “Is intracellular hyperthermia superior to extracellular hyperthermia in the thermal sense?” International Journal of Hyperthermia, vol. 18, no. 3, pp. 194–202, 2002. View at Publisher · View at Google Scholar · View at Scopus
  32. G. Chen, “Ballistic-diffusive heat-conduction equations,” Physical Review Letters, vol. 86, no. 11, pp. 1197–2300, 2000. View at Publisher · View at Google Scholar
  33. E. H. Wissler, “Pennes' 1948 paper revisited,” Journal of Applied Physiology, vol. 85, no. 1, pp. 35–41, 1998. View at Scopus
  34. T. C. Shih, P. Yuan, W. L. Lin, and H. S. Kou, “Analytical analysis of the Pennes bioheat transfer equation with sinusoidal heat flux condition on skin surface,” Medical Engineering & Physics, vol. 29, no. 9, pp. 946–953, 2007. View at Publisher · View at Google Scholar · View at Scopus
  35. P. Yuan, H. E. Liu, C. W. Chen, and H. S. Kou, “Temperature response in biological tissue by alternating heating and cooling modalities with sinusoidal temperature oscillation on the skin,” International Communications in Heat and Mass Transfer, vol. 35, no. 9, pp. 1091–1096, 2008. View at Publisher · View at Google Scholar · View at Scopus
  36. J. Liu and L. X. Xu, “Estimation of blood perfusion using phase shift in temperature response to sinusoidal heating at the skin surface,” IEEE Transactions on Biomedical Engineering, vol. 46, no. 9, pp. 1037–1043, 1999. View at Publisher · View at Google Scholar · View at Scopus
  37. I. K. Tjahjono, An analytical model for near-infrared light heating of a slab by embedded gold nanoshells [Ph.D. thesis], Rice University, 2006.
  38. P. Keblinski, D. G. Cahill, A. Bodapati, C. R. Sullivan, and T. A. Taton, “Limits of localized heating by electromagnetically excited nanoparticles,” Journal of Applied Physics, vol. 100, no. 5, Article ID 054305, 5 pages, 2006. View at Publisher · View at Google Scholar · View at Scopus
  39. E. Gescheidtova, R. Kubásek, and K. Bartušek, “Quality of gradient magnetic fields estimation,” Journal of EE, vol. 57, no. 8, pp. 54–57, 2006.
  40. M. Squibb, “A guide to experimental exposure of biological tissue to pulsed magnetic fields,” PEMF Usage Guide, 2007.
  41. G. C. Goats, “Pulsed electromagnetic (short-wave) energy therapy,” British Journal of Sports Medicine, vol. 23, no. 4, pp. 213–216, 1989. View at Scopus
  42. T. Niwa, Y. Takemura, N. Aida, H. Kurihara, and T. Hisa, “Implant hyperthermia resonant circuit produces heat in response to MRI unit radiofrequency pulses,” The British Journal of Radiology, vol. 81, no. 961, pp. 69–72, 2008. View at Publisher · View at Google Scholar · View at Scopus
  43. P. Cantillon-Murphy, L. L. Wald, M. Zahn, and E. Adalsteinsson, “Proposing magnetic nanoparticle hyperthermia in low-field MRI,” Concepts in Magnetic Resonance A, vol. 36, no. 1, pp. 36–47, 2010. View at Publisher · View at Google Scholar · View at Scopus
  44. S. M. Morgan and R. H. Victora, “Use of square waves incident on magnetic nanoparticles to induce magnetic hyperthermia for therapeutic cancer treatment,” Applied Physics Letters, vol. 97, no. 9, Article ID 093705, 3 pages, 2010. View at Publisher · View at Google Scholar · View at Scopus
  45. K. E. Oughstun, Electromagnetic and Optical Pulse Propagation, Springer, 2006.
  46. L. R. Squire and J. A. Zouzounis, “ECT and memory: brief pulse versus sine wave,” The American Journal of Psychiatry, vol. 143, no. 5, pp. 596–601, 1986. View at Scopus
  47. R. Kappiyoor, M. Liangruksa, R. Ganguly, and I. K. Puri, “The effects of magnetic nanoparticle properties on magnetic fluid hyperthermia,” Journal of Applied Physics, vol. 108, no. 9, Article ID 094702, 8 pages, 2010. View at Publisher · View at Google Scholar · View at Scopus
  48. A. Trakic, F. Liu, and S. Crozier, “Transient temperature rise in a mouse due to low-frequency regional hyperthermia,” Physics in Medicine and Biology, vol. 51, no. 7, pp. 1673–1691, 2006. View at Publisher · View at Google Scholar · View at Scopus
  49. A. O. Govorov, W. Zhang, T. Skeini, H. Richardson, E. J. Lee, and N. A. Kotov, “Gold nanoparticle ensembles as heaters and actuators: melting and collective plasmon resonances,” Nanoscale Research Letters, vol. 1, no. 1, pp. 84–90, 2006. View at Publisher · View at Google Scholar · View at Scopus
  50. O. N. Strand, “A method for the computation of the error function of a complex variable,” Mathematics of Computation, vol. 19, pp. 127–129, 1965.
  51. J. Kestin and L. N. Persen, “On the error function of a complex argument,” Zeitschrift für Angewandte Mathematik und Physik, vol. 7, no. 1, pp. 33–40, 1956. View at Publisher · View at Google Scholar · View at Scopus
  52. M. Kettering, J. Winter, M. Zeisberger et al., “Magnetic nanoparticles as bimodal tools in magnetically induced labelling and magnetic heating of tumour cells: an in vitro study,” Nanotechnology, vol. 18, no. 17, Article ID 175101, 9 pages, 2007. View at Publisher · View at Google Scholar · View at Scopus
  53. R. Hergt, S. Dutz, R. Müller, and M. Zeisberger, “Magnetic particle hyperthermia: nanoparticle magnetism and materials development for cancer therapy,” Journal of Physics, vol. 18, no. 38, pp. S2919–S2934, 2006. View at Publisher · View at Google Scholar · View at Scopus
  54. I. Hilger, R. Hergt, and W. A. Kaiser, “Use of magnetic nanoparticle heating in the treatment of breast cancer,” IEE Proceedings-Nanobiotechnology, vol. 152, no. 1, pp. 33–39, 2005. View at Publisher · View at Google Scholar · View at Scopus
  55. A. A. Velayati, P. Farnia, and T. A. Ibrahim, “Differences in cell wall thickness between resistant and nonresistant strains of Mycobacterium tuberculosis: using transmission electron microscopy,” Chemotherapy, vol. 55, no. 5, pp. 303–307, 2009. View at Publisher · View at Google Scholar · View at Scopus
  56. V. Dupres, Y. F. Dufreěne, and J. J. Heinisch, “Measuring cell wall thickness in living yeast cells using single molecular rulers,” American Chemical Society Nano, vol. 4, no. 9, pp. 5498–5504, 2010. View at Publisher · View at Google Scholar · View at Scopus
  57. “What is the thickness of the cell membrane?” http://www.weizmann.ac.il/plants/Milo/images/membraneThickness110109RM.pdf.
  58. M. Kaiser, J. Heintz, I. Kandela, and R. Albrecht, “Tumor cell death induced by membrane melting via immunotargeted, inductively heated core/shell nanoparticles,” Microscopy and Microanalysis, vol. 13, supplement 2, pp. 18–19, 2007.
  59. J. Vera and Y. Bayazitoglu, “Gold nanoshell density variation with laser power for induced hyperthermia,” International Journal of Heat and Mass Transfer, vol. 52, no. 3-4, pp. 564–573, 2009. View at Publisher · View at Google Scholar · View at Scopus
  60. E. I. Gabrielle, Biology The Easy Way, Barron's Educational Series, New York, NY, USA, 1990.
  61. B. Chan, B. D. Chithrani, A. A. Ghazani, and C. W. Warren, “Determining the size and shape dependence of gold nanoparticle uptake into mammalian cells,” Nano Letters, vol. 6, no. 4, pp. 662–668, 2006. View at Publisher · View at Google Scholar · View at Scopus
  62. Z. Yang, Z. W. Liu, R. P. Allaker et al., “A review of nanoparticle functionality and toxicity on the central nervous system,” Journal of the Royal Society Interface, vol. 7, no. 4, pp. S411–S422, 2010. View at Publisher · View at Google Scholar · View at Scopus
  63. N. Singha, G. J. S. Jenkinsa, R. Asadib, and S. H. Doaka, “Potential toxicity of superparamagnetic iron oxide nanoparticles,” Nano Reviews, vol. 1, pp. 1–15, 2010.
  64. H. Huang, Magnetic nanoparticles based magnetophresis for efficient separation of foodborne pathogenes [M.S. thesis], University of Arkansa, 2009.
  65. M. P. Melancon, W. Lu, Z. Yang et al., “In vitro and in vivo targeting of hollow gold nanoshells directed at epidermal growth factor receptor for photothermal ablation therapy,” Molecular Cancer Therapeutics, vol. 7, no. 6, pp. 1730–1739, 2008. View at Publisher · View at Google Scholar · View at Scopus
  66. P. H. Linh, N. C. Thuan, N. A. Tuan et al., “Invitro toxicity test and searching the possibility of cancer cell line extermination by magnetic heating with using Fe3O4 magnetic fluid,” Journal of Physics, vol. 187, no. 1, Article ID 012008, 9 pages, 2009. View at Publisher · View at Google Scholar · View at Scopus
  67. S. Balivada, R. S. Rachakatla, H. Wang et al., “A/C magnetic hyperthermia of melanoma mediated by iron(0)/iron oxide core/shell magnetic nanoparticles: a mouse study,” Bio Med Centeral Cancer, vol. 10, article 119, 9 pages, 2010. View at Publisher · View at Google Scholar · View at Scopus
  68. S. Bedanta and W. Kleemann, “Supermagnetism,” Journal of Physics D, vol. 42, no. 1, Article ID 013001, 28 pages, 2009. View at Publisher · View at Google Scholar · View at Scopus
  69. M. Lewin, N. Carlesso, C. H. Tung et al., “Tat peptide-derivatized magnetic nanoparticles allow in vivo tracking and recovery of progenitor cells,” Nature Biotechnology, vol. 18, no. 4, pp. 410–414, 2000. View at Publisher · View at Google Scholar · View at Scopus
  70. S. Purushotham and R. V. Ramanujan, “Modeling the performance of magnetic nanoparticles in multimodal cancer therapy,” Journal of Applied Physics, vol. 107, no. 11, Article ID 114701, 9 pages, 2010. View at Publisher · View at Google Scholar · View at Scopus
  71. J. S. Walker, Encyclopedia of Physical Science and Technology, Elsevier Science, 3th edition, 2003.
  72. S. W. Smith, The Scientist and Engineer's Guide to Digital Signal Processing, chapter 13, California Technical Publishing, 1997.
  73. J. Pellicer-Porres, R. Lacomba-Perales, J. Ruiz-Fuertes, D. Martínez-García, and M. V. Andrés, “Force characterization of eddy currents,” American Journal of Physics, vol. 74, no. 4, pp. 267–271, 2006. View at Publisher · View at Google Scholar · View at Scopus