Research Article

Quality Assessment of Transient Response Analysis Method for Detecting Radiation-Induced Faults

Table 1

Nominal values, LSL and USL of the functional specifications of the filters.

Filter 1Filter 2
(rad/s) (rad/s)

LSL 1.000 0.636
Nominal value 1.111 0.707
USL 1.222 0.778