Research Article

Performance Study of Solar Air Heater Having Absorber Plate with Half-Perforated Baffles

Table 2

Values of different parameters for performance prediction of baffled duct solar air heater.

Collector width, W 1 m
Collector length, L 2 m
Duct height, H 35 mm
Gap between absorber plate and glass cover50 mm
Collector slope, β0° for horizontal
Number of glass covers1
Transmittance-absorptance product, τα0.8 for single glass cover
Thickness of glass cover4 mm
Thermal conductivity of glass cover0.78 Wm−1 K−1
Thermal conductivity of back insulation material (Thermocol)0.037 Wm−1 K−1
Back insulation thickness50 mm
Long wave emissivity0.88 for glass cover
0.95 for absorber with flat
black paint
Relative baffle height, e/H 0.495
Relative baffle pitch, p/e 7.0
Sky temperature, Ts= Ta
Ambient temperature, Ta285–315 K
Wind heat transfer coefficient, 𝑤 5 and 10 Wm−2 K−1
Solar insolation, I 500 and 800 Wm−2